ST_SetPositionOptions
This data type contains the optional settings for the function block MC_SetPosition.
TYPE ST_SetPositionOptions
STRUCT
ClearPositionLag : BOOL;
SelectEncoderIndex : BOOL;
EncoderIndex : UINT;
ClearPositionOffset : BOOL;
END_STRUCT
END_TYPEClearPositionOffset – deleting the MC_SetPosition offset
The position offset totaled by the MC_SetPosition call can be deleted with this function block. To do this, the ClearPositionOffset switch is set in the options; the position transferred to the block is not relevant in this case.
![]() | This option is available from TwinCAT 3.1.4024.51 and Tc2_MC2 3.3.56. |
VAR
mcSetPositionClear: MC_SetPosition;
END_VARmcSetPositionClear.Options.ClearPositionOffset := TRUE;
mcSetPositionClear (
Axis:= Axis,
Position:= , // not relevant
Execute:= TRUE);Homing the axis, e.g. with MC_Home, produces a newly referenced coordinate system for the axis and also deletes the offset.