AX200x Profibus Parameter Number
| PNU | Data type | Access | Short description | SERVOSTAR™ASCII command | 
|---|---|---|---|---|
| Profile parameter | ||||
| 904 | UINT32 | ro | Number of the supported PPO write, always 2 | - | 
| 911 | UINT32 | ro | Number of the supported PPO read, always 2 | - | 
| 918 | UINT32 | ro | Device address on the PROFIBUS | ADDR | 
| 930 | UINT32 | r/w | Selection switch for operating mode | - | 
| 963 | UINT32 | ro | PROFIBUS baud rate | - | 
| 965 | Octet-String2 | ro | Number of the PROFIDRIVE profile (0302H) | - | 
| 970 | UINT32 | wo | Load default parameter set | RSTVAR | 
| 971 | UINT32 | wo | Store parameter in non-volatile memory | SAVE | 
| SERVOSTAR™ manufacturer-specific parameters | ||||
| General parameters | ||||
| 1000 | Visible String4 | ro | Device identifier | - | 
| 1001 | UINT32 | ro | Manufacturer-specific error register | ERRCODE | 
| 1002 | UINT32 | ro | Manufacturer-specific status register | - | 
| Speed controller parameters | ||||
| 1200 | UINT32 | r/w | Kp - amplification factor of the speed controller | GV | 
| 1201 | UINT32 | r/w | Tn – integral-action time of the speed controller | GVTN | 
| 1202 | UINT32 | r/w | PID – T2 – time constant for the speed controller | GVT2 | 
| 1203 | UINT32 | r/w | Set value ramp+, speed controller | ACC | 
| 1204 | UINT32 | r/w | Set value ramp-, speed controller | DEC | 
| 1205 | UINT32 | r/w | Emergency ramp, speed controller | DECSTOP | 
| 1206 | UINT32 | r/w | Maximum rotation speed | VLIM | 
| 1207 | UINT32 | r/w | Overspeed | VOSPD | 
| 1208 | UINT32 | r/w | Counting direction | DIR | 
| Position controller parameters | ||||
| 1250 | UINT32 | r/w | Multiplier for speeds jogging/ref. | VMUL | 
| 1251 | UINT32 | r/w | Axis type | POSCNFG | 
| 1251 | INTEGER32 | r/w | In-position window | PEINPOS | 
| 1253 | INTEGER32 | r/w | Following error window | PEMAX | 
| 1254 | INTEGER32 | r/w | Position register 1 | SWE1 | 
| 1255 | INTEGER32 | r/w | Position register 2 | SWE2 | 
| 1256 | INTEGER32 | r/w | Position register 3 | SWE3 | 
| 1257 | INTEGER32 | r/w | Position register 4 | SWE4 | 
| 1258 | UINT32 | r/w | Resolution denominator | PGEARO | 
| 1259 | UINT32 | r/w | Resolution numerator | PGEARI | 
| 1260 | UINT32 | r/w | Minimum acceleration or braking time | PTMIN | 
| 1261 | UINT32 | r/w | Position controller feed-forward factor | GPFFV | 
| 1262 | UINT32 | r/w | Position controller KV factor | GP | 
| 1263 | UINT32 | r/w | Position controller KP factor | GPV | 
| 1264 | UINT32 | r/w | Tn - position controller integral-action time | GPTN | 
| 1265 | UINT32 | r/w | Maximum speed for positioning operation | PVMAX | 
| 1266 | UINT32 | r/w | Configuration variable for software switch | SWCNFG | 
| 1267 | UINT32 | r/w | Configuration variable 2 for software switch | SWCNFG2 | 
| Positioning data for position controller mode | ||||
| 1300 | INTEGER32 | r/w | Position | O_P | 
| 1301 | INTEGER16 | r/w | Velocity | O_V | 
| 1302 | UINT32 | r/w | Transport instruction type | O_C | 
| 1304 | UINT32 | r/w | Starting up time (acceleration) | O_ACC1 | 
| 1305 | UINT32 | r/w | Braking time (deceleration) | O_DEC1 | 
| 1306 | UINT32 | r/w | Jerk limitation (acceleration) | O_ACC2 | 
| 1307 | UINT32 | r/w | Jerk limitation (deceleration) | O_DEC2 | 
| 1308 | UINT32 | r/w | Number of the subsequent transport instruction | O_FN | 
| 1309 | UINT32 | r/w | Start delay for subsequent transport instruction | O_FT | 
| 1310 | 2 * UINT16 | wo | Copy a transport instruction | OCOPY | 
| Setting-up mode, position | ||||
| 1350 | UINT32 | r/w | Reference travel type | NREF | 
| 1351 | UINT32 | r/w | Reference travel direction | DREF | 
| 1352 | UINT32 | r/w | Acceleration ramp (jogging/referencing) | ACCR | 
| 1353 | UINT32 | r/w | Braking ramp | DECR | 
| 1354 | UINT32 | r/w | Reference offset | ROFFS | 
| 1355 | UINT32 | ro | Reference travel speed | VREF | 
| 1356 | UINT32 | ro | Jogging speed | VJOG | 
| Actual values | ||||
| 1400 | INTEGER32 | ro | Actual position represented with 20 bits/rotation | PRD | 
| 1401 | INTEGER32 | ro | Speed | - | 
| 1402 | INTEGER32 | ro | Incremental actual position value | - | 
| 1403 | INTEGER32 | ro | SI - actual position value | PFB | 
| 1404 | INTEGER32 | ro | SI - actual speed value | PV | 
| 1405 | INTEGER32 | ro | SI - following error | PE | 
| 1406 | INTEGER32 | ro | Effective current | I | 
| 1407 | INTEGER32 | ro | SI - actual rotation speed | V | 
| 1408 | INTEGER32 | ro | Heatsink temperature | TEMPH | 
| 1409 | INTEGER32 | ro | Internal temperature | TEMPE | 
| 1410 | INTEGER32 | ro | DC link voltage | VBUS | 
| 1411 | INTEGER32 | ro | Ballast power | PBAL | 
| 1412 | INTEGER32 | ro | I2t - loading | I2T | 
| 1413 | INTEGER32 | ro | Period of operation | TRUN | 
| Digital I/O-configuration | ||||
| 1450 | UINT32 | r/w | Function of digital input 1 | IN1MODE | 
| 1451 | UINT32 | r/w | Function of digital input 2 | IN2MODE | 
| 1452 | UINT32 | r/w | Function of digital input 3 | IN3MODE | 
| 1453 | UINT32 | r/w | Function of digital input 4 | IN4MODE | 
| 1454 | INTEGER32 | r/w | Auxiliary variable for digital input 1 | IN1TRIG | 
| 1455 | INTEGER32 | r/w | Auxiliary variable for digital input 2 | IN2TRIG | 
| 1456 | INTEGER32 | r/w | Auxiliary variable for digital input 3 | IN3TRIG | 
| 1457 | INTEGER32 | r/w | Auxiliary variable for digital input 4 | IN4TRIG | 
| 1458 | INTEGER32 | r/w | Function of digital output 1 | O1MODE | 
| 1459 | INTEGER32 | r/w | Function of digital output 2 | O2MODE | 
| 1460 | UINT32 | r/w | Auxiliary variable for digital output 1 | O1TRIG | 
| 1461 | UINT32 | r/w | Auxiliary variable for digital output 2 | O2TRIG | 
| 1462 | UINT32 | r/w | State of 4 digital inputs, enable, 2 digital outputs | STATIO | 
| Analog configuration | ||||
| 1500 | UINT32 | r/w | Configuration of the analog input functions | ANCNFG | 
| 1501 | UINT32 | r/w | Configuration of monitor function for analog output 1 | ANOUT1 | 
| 1502 | UINT32 | r/w | Offset voltage for analog input 1 | ANOFF1 | 
| 1503 | UINT32 | r/w | Filter time constant for analog input 1 | AVZ1 | 
| 1504 | UINT32 | r/w | Speed scaling factor for analog input 1 | VSCALE1 | 
| 1505 | UINT32 | r/w | Current scaling factor for analog input 1 | ISCALE1 | 
| 1506 | UINT32 | r/w | Configuration of monitor function for analog output 2 | ANOUT2 | 
| 1507 | UINT32 | r/w | Offset voltage for analog input 2 | ANOFF2 | 
| 1508 | UINT32 | r/w | Speed scaling factor for analog input 2 | VSCALE2 | 
| 1509 | UINT32 | r/w | Current scaling factor for analog input 2 | ISCALE2 | 
| Motor parameters | ||||
| 1550 | UINT32 | r/w | Brake configuration | MBRAKE | 
| 1551 | UINT32 | r/w | Motor number from the motor database | MNUMBER |