Controller Errors
Error(Hex) | Error(Dec) | Error type | Description | |
|---|---|---|---|---|
4500 | 17664 | Parameter | Controller ID not allowed The value for the controller ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is greater than 255. | |
Value range: [1 ... 255] | Unit: 1 | |||
4501 | 17665 | Parameter | Controller type not allowed The value for the controller type is unacceptable because it is not defined. | |
Value range: [1 ... 9] | Unit: 1 | |||
4502 | 17666 | Parameter | Operation mode controller not allowed The value for the controller operating mode is not allowed. | |
Value range: [1] | Unit: 1 | |||
4503 | 17667 | Parameter | Weighting of the velocity pre-control not allowed The value for the percentage weighting of the velocity pre-control is not allowed. The parameter is pre-set to 1.0 (100%) as standard. | |
Value range: [0.0 ... 1.0] | Unit: % | |||
4504 | 17668 | Parameter | Lag error monitor (position) not allowed The value for the activation of the lag error monitor is not allowed. | |
Value range: [0, 1] | Unit: 1 | |||
4505 | 17669 | Parameter | Lag monitoring (velocity) not allowed The value for the activation of the lag error monitoring (velocity) is not allowed. | |
Value range: [0, 1] | Unit: 1 | |||
4506 | 17670 | Parameter | Lag error window (position) not allowed The value for the lag error window (maximum allowable lag error) is not allowed. | |
Value range: [0.0, 10000.0] | Unit: e.g. mm | |||
4507 | 17671 | Parameter | Lag error filter time (position) not allowed The value for the lag error filter time (position) is not allowed. | |
Value range: [0.0, 600.0] | Unit: s | |||
4508 | 17672 | Parameter | Lag error window (velocity) not allowed The value for the lag error window (velocity) is not allowed. | |
Value range: [0.0, 10000.0] | Unit: e.g. m/min | |||
4509 | 17673 | Parameter | Lag error filter time (velocity) not allowed The value for the lag error filter time (velocity) is not allowed. | |
Value range: [0.0, 600.0] | Unit: s | |||
450A | 17674 | Parameter | Controller output limitation (output limitation) not allowed The value for the output limitation of the controller at the total manipulated variable is invalid. The default setting is 0.5 (50 percent). Typically, this parameter is effective if the velocity interface has been parameterized for the drive unit and the | |
Value range: [0.0, 1.0] | Unit: % | |||
4510 | 17680 | Parameter | Proportional gain Kv or Kp (controller) not allowed Position The value for the proportional gain (Kv factor or Kp factor) is not allowed. | |
Value range: [0.0, 10000.0] | Unit: e.g. mm/s/mm | |||
4511 | 17681 | Parameter | Integral action time Tn (controller) not allowed Position The value for the integral action time is not allowed (I part of the PID T1 controller). | |
Value range: [0.0, 60.0] | Unit: s | |||
4512 | 17682 | Parameter | Rate time Tv (controller) not allowed Position The value for the derivative action time is not allowed (D part of the PID T1 controller). | |
Value range: [0.0, 60.0] | Unit: s | |||
4513 | 17683 | Parameter | Damping time Td (controller) not allowed Position The value for the damping time is not allowed (D part of the PID T1 controller). | |
Value range: [0.0, 60.0] | Unit: s | |||
4514 | 17684 | Function | Activation of the automatic offset calibration not allowed Activation of the automatic offset calibration is only possible for certain types of controller (with no I component). | |
4515 | 17685 | Parameter | Additional proportional gain Kv or Kp (controller) not allowed Position The value for the second term of the proportional gain (Kv factor or Kp factor) is not allowed. | |
Value range: [0.0, 10000.0] | Unit: e.g. mm/s/mm | |||
4516 | 17686 | Parameter | Reference velocity for additional proportional gain Kv or Kp (controller) not allowed Position The value for the reference velocity percentage data entry, to which the additional proportional gain is applied, is not allowed. The standard setting for the parameter is 0.5 (50%). | |
Value range: [0.0 ... 1.0] | Unit: % | |||
4517 | 17687 | Parameter | Proportional gain Pa (proportion) not allowed Acceleration The value for the proportional gain (Pa factor) is not allowed. | |
Value range: [0.0, 1000000.0] | Unit: s | |||
4518 | 17688 | Parameter | Proportional gain Kv (controller) not allowed Velocity The value for the proportional gain (Kv factor) is not allowed. | |
Value range: [0.0, 10000.0] | Unit: 1 | |||
4519 | 17689 | Parameter | Integral action time Tn (controller) not allowed Velocity The value for the integral action time is not allowed (I part of the PID T1 controller). | |
Value range: [0.0, 60.0] | Unit: s | |||
451A | 17690 | Parameter | Reserved Reserved, currently not used. | |
451B | 17691 | Parameter | Reserved Reserved, currently not used. | |
451C | 17692 | Parameter | Velocity filter time not allowed The parameter for the velocity filter time in seconds is invalid ( | |
Value range: [0.0, 60.0] | Unit: s | |||
451D | 17693 | Parameter | Dead range not allowed The value for the dead range (neutral zone) of the position error or the velocity error (control deviation) is not allowed (applies to more complex controllers with velocity or torque interface). | |
Value range: [0.0, 10000.0] | Unit: mm or mm/s | |||
451F | 17695 | Parameter | Proportional gain Kcp not allowed The parameter for the proportional gain | |
Value range: [0.0, 10000.0] | Unit: e.g. mm^2/mm | |||
4520 | 17696 | Parameter | Rate time Tv (controller) not allowed Velocity The value for the derivative action time is not allowed (D part of the PID T1 controller). | |
Value range: [0.0, 60.0] | Unit: s | |||
4521 | 17697 | Parameter | Damping time Td (controller) not allowed Velocity The value for the damping time is not allowed (D part of the PID T1 controller). Suggested value: 0.1 * Tv | |
Value range: [0.0.. 60.0] | Unit: s | |||
4522 | 17698 | Parameter | Limitation of the I part not allowed The parameter for limiting the | |
Value range: [0.0 .. 1.0] | Unit: % | |||
4523 | 17699 | Parameter | Limitation of the D part not allowed The parameter for limiting the | |
Value range: [0.0 .. 1.0] | Unit: % | |||
4524 | 17700 | Parameter | Parameter 'Deactivation of the I part during travel' not allowed The boolean parameter for switching off the | |
Value range: [0, 1] | Unit: 1 | |||
4525 | 17701 | Parameter | Parameter 'Filter time for P-T2 filter' not allowed The time | |
Value range: [0.0, 60.0] | Unit: s | |||
4526 | 17702 | Parameter | Velocity observer: 'Parameterized mode' is not allowed The parameterized mode ( | |
Value range: [0, 1] | Unit: 1 | |||
4527 | 17703 | Parameter | Velocity observer: 'Motor torque constant Kt or Kf' is not allowed The parameter for the motor torque constant | |
Value range: [0.0 .. 100000.0] | Unit: Nm/A or N/A | |||
4528 | 17704 | Parameter | Velocity observer: 'Motor moment of inertia JM' is not allowed The parameter for the motor moment of inertia JM of the velocity observer of the special NC controller in the torque interface is invalid. | |
Value range: [0.0001 .. 100000.0] | Unit: kg cm^2 | |||
4529 | 17705 | Parameter | Velocity observer: 'Bandwidth f0' is not allowed The parameter for the bandwidth f0 of the velocity observer of the special NC controller in the torque interface is invalid. The bandwidth must be less than the reciprocal of 6 times the NC cycle time (f0 < 1/(6*T)). | |
Value range: [0.0 .. 10000.0] | Unit: Hz | |||
452A | 17706 | Parameter | Velocity observer: 'Correction factor kc' is not allowed The parameter for the correction factor kc of the velocity observer of the special NC controller in the torque interface is invalid. The correction factor kc establishes the relationship between current and acceleration or angular acceleration. | |
Value range: [0.0 .. 100.0] | Unit: s | |||
452B | 17707 | Parameter | Velocity observer: 'Time constant T for 1st order filter' is not allowed The time constant | |
Value range: [0.0 .. 100.0] | Unit: s | |||
452C | 17708 | Parameter | Velocity observer: 'Amplitude damping d for 2nd order filter' is not allowed The high-pass/low-pass amplitude attenuation dHP or dTP for the 2nd order velocity filter ("bi-quad") of the velocity observer of the special NC controller in the torque interface is not allowed. | |
Value range: [0.2 .. 10.0] | Unit: 1 | |||
452D | 17709 | Parameter | Velocity observer: 'Frequency fHP or fTP for 2nd order filter' is not allowed The high-pass/low-pass frequency fHP or fTP for the 2nd order velocity filter ("bi-quad") of the velocity observer of the special NC controller in the torque interface is not allowed. | |
Value range: [0.0, ... 10000.0] | Unit: Hz | |||
4540 | 17728 | Initialization | Controller initialization The controller has not been initialized. Although the controller has been created, the rest of the initialization has not been performed (1. Initialization of controller, 2. Reset of controller). | |
4541 | 17729 | Address | Axis address The controller does not know its axis, or the axis address has not been initialized. | |
4542 | 17730 | Address | Drive address The controller does not know its drive, or the drive address has not been initialized. | |
4550 | 17744 | Monitoring | Lag error monitor (position) While the lag error monitor was active (position), the lag error was exceeded by an amount greater than the lag error window and which lasting longer than the parameterized lag error filter time. | |
4551 | 17745 | Monitoring | Lag monitoring (velocity) With active lag error monitoring (velocity) a velocity lag error exceedance has occurred, whose magnitude is greater than the lag error window, and whose duration is longer than the parameterized lag error filter time. | |
45A0 | 17824 | Monitoring | Internal error CONTROLERR_RANGE_AREA_ASIDE | |
45A1 | 17825 | Monitoring | Internal error CONTROLERR_RANGE_AREA_BSIDE | |
45A2 | 17826 | Monitoring | Internal error CONTROLERR_RANGE_QNENN | |
45A3 | 17827 | Monitoring | Internal error CONTROLERR_RANGE_PNENN | |
45A4 | 17828 | Monitoring | Internal error CONTROLERR_RANGE_AXISIDPRESP0 | |