HintTextColor
This property sets or returns the color that is used to display hints. The hint had been issued from the PLC function block ADSLOGEVENT by setting the flag from FALSE to TRUE (or other ADS device) or the from a call to a Report Event Function like ITcEventLogC::ReportEvent,ITcEventC3::ReportEventEx or ITcEventLog::ReportEvent with the TcEventClass set to TCEVENTCLASS_HINT.
Property get
HRESULT get_HintTextColor([out, retval] OLE_COLOR* pVal);
Parameters
pVal
[out, retval] pointer to OLE_COLOR variable that receives the text color that is used to display hints.#
Return Values
| S_OK Function was successfully called E_POINTER pVal was no valid pointer 
 | 
Property let
HRESULT put_HintTextColor([in] OLE_COLOR newVal);
Parameters
newVal
[in] A variable that sets the text color that is used to display hints.
Return Values
S_OK
Function was successfully called
| 
 | 
Visual Basic sample code
Option Explicit
' add the Beckhoff TcEvent View Library to the components
' place a TcEventView on the form, and assign the name
TcEventView1
Private Sub Form_Load()
' display hints with red text color
TcEventView1.HintTextColor = RGB(255, 0, 0)
End Sub