Setting the corner deceleration parameter values
#SET CORNER PARAM [ <expr_1>, <expr_2> <expr_3> ] (modal)
<expr_1> Distance between corners in mm
<expr_2> Corner feed rate unit (<expr_3>)
0: According to F word
1: Percent [%]
<expr_3> Corner feed rate
Specifying a distance between corners permits the point in the space to be computed from which onwards the path feed rate shall be reduced as a linear function of the distance. Here, the following definition applies:
The distance between corners that is to be programmed is related to the corrected path, not to the originally programmed target points.
The #SET command must be on a separate NC line. This means that further NC commands are not permitted in the same block.
![]() | The corner deceleration is only effective in combination with the linear slope[1]-26 . |
Fig.48: Illustration of feed at a circular inside contour 