MCV_ConveyorControl

With the MCV_ConveyorControl function block the state of the dynamic behavior of an axis is sent to the motion controller. This is done for an axis that isn’t under control of the motion controller, because the axis is configured as encoder axis (see P-AXIS-00015).

This information influences the synchronization motion of an axes group that is synchronized with that encoder axis, because the encoder axis is configured as master axis of the axes group.

Block diagram

MCV_ConveyorControl 1:

Parameters of the function block

VAR_IN_OUT

 

Axis

AXIS_REF

Axis reference

VAR_INPUT

 

Enable

BOOL

TRUE, state of dynamic behavior is sent to the motion controller

 

ControlMode

UDINT

Actual dynamic behavior of the axis.

Allowed values are:

0: HLI_CONVEYOR_SPEED_CONST

1: HLI_CONVEYOR_ACCELERATION

2: HLI_CONVEYOR_DECELERATION

3: HLI_CONVEYOR_SPEED_ZERO

VAR_OUTPUT

 

Valid

BOOL

TRUE, value at output ActiveControlMode is valid.

 

ActiveControlMode

UDINT

Actual dynamic behavior of the encoder axis, which was delivered to the motion controller.

 

Error

BOOL

Indicates if an error has occurred.

 

ErrorID

WORD

Error identification.

Behavior of the FB: