MCV_SetTorqueValue
The value for the maximum torque in ±0.1% is set with the MCV_SetTorqueValue FB.
Block diagram

Parameters of the function block
| VAR_IN_OUT | ||
| Axis | AXIS_REF | Axis reference. |
VAR_INPUT | |||
| Enable | BOOL | Activates torque for drive mode torque control. |
| TorqueValue | INT | Maximum torque value. Unit [0.1%] |
VAR_OUTPUT | |||
| ActiveTorqueCommand | BOOL | Torque is active. |
| ActualTorqueValue | INT | Current torque value. Unit [0.1%] |
| Error | BOOL | Indicates if an error has occurred. |
| ErrorID | WORD | Error identification. |
Behavior of the function block
The maximum torque is entered in the value range -1000 ≤ 0 ≤ +1000. The unit is 0.1% of the maximum torque, in the positive or negative direction of rotation.
The entered value is active as soon as "Enable’ is set to TRUE. The entered value is accepted immediately if the function block is permanently activated.