Requested and commanded user data
Content of message to/from PLC | |
Description | Data of message which was received or sent. |
ST path | Commanded vlue pMC[channel_idx]^.addr^.MsgMcControl_Data.CommandW Requested value pMC[channel_idx]^.addr^.MsgMcControl_Data.RequestR |
ST element | . Inhalt |
Data type | ARRAY [ 1 .. GCW_250_HliMessageLaenge] OF BYTE |
Type of message to/from PLC | |
Description | Marks if a message was sent by CNC using #MSG or #MSGINFO command (see [PROG]) |
ST path | Commanded value pMC[channel_idx]^.addr^.MsgMcControl_Data.CommandW Requested Wert pMC[channel_idx]^.addr^. MsgMcControl_Data.RequestR |
ST element | . Typ |
Data type | UDINT |
Value range | 0 Initial value 1 Type of message which was sent using #MSG command (if CNC sent the 2 Type of message, which was sent using #MSGINFO command (if CNC sent |