User data
Axis number | |
Description | Number of logical axis unique system-wide. The specified logical axis is assigned the speed with which it is to be moved in Manual mode in Inching operating mode. |
ST path | Commanded value pMC[channel_idx]^.addr^.MCControlHB_Data.HBTipParameterControlUnit_TipParameter.HBTipParameter_Command.W_LogAchsNr Requested value pMC[channel_idx]^.addr^.MCControlHB_Data.HBTipParameterControlUnit_TipParameter.HBTipParameter_Request.W_LogAchsNr |
Data type | UINT |
Value range | [1, nAxis] |
Inching speed | |
Description | Speed to be assigned to the logical axis in Inching mode. |
ST path | Commanded value pMC[channel_idx]^.addr^.MCControlHB_Data.HBTipParameterControlUnit_TipParameter.HBTipParameter_Command.D_Speed Requested value pMC[channel_idx]^.addr^.MCControlHB_Data.HBTipParameterControlUnit_TipParameter.HBTipParameter_Request.D_Speed |
Unit | 1 µm/s |
Data type | UDINT |