User data

Axis number

Description

Number of a logical axis unique system-wide.

The specified logical axis is assigned the operating device via which the axis is to be moved in Manual mode.

ST path

Commanded value

pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Command.W_LogAchsNr

Requested value pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Request.W_LogAchsNr

Data type

UINT

Value range

[1, nAxis]

Operating device number

Description

Number of the logical operating device to be assigned to the logical axis.

ST path

Commanded value

pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Command.W_ControlElement

Requested value pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Request.W_ControlElement

Data type

UINT

Value range

One of the values defined in the configuration list hand_mds.lis for the characteristic parameters tasten_data[X].log_tasten_nr as logical inching key pair number if the operating device comprises a key pair.

or

One of the values defined in the configuration list hand_mds.lis for the characteristic parameters hr_data[0].log_hr_nr as logical handwheel numbers if the operating device is a handwheel.

Characteristics

If 0 is predefined for a logical number, the current operation mode of an axis is deselected.

Manual operating mode

Description

Manual operating mode to be assigned to the logical axis.

ST path

Commanded value

pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Command.W_OperationMode

Requested value pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Request.W_OperationMode

Data type

UINT

Value range

0 No operating mode (deselection)

1 Handwheel mode

2 Inching mode

3 Jog mode

Manual mode parameter record

Description

Definition of the index of the parameter record, that should be used for the manual mode.

ST path

Commanded value
pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Command.W_ParameterIndex

Requested value
pMC[channel_idx]^.addr^.MCControlHB_Data.HBActivationControlUnit_Activation.HBActivation_Request.W_ParameterIndex

Data type

UINT

Value range

[0; 2]

Characteristics

After input of individual parameters via the PLC-interface the first value record of the parameter table (index=0) is overwritten. The residual parameter records are not changed. This means, they corresponds to the values defined in the axis specific parameter lists.

Remark:

The current active axis can be deselected by deactivation of the operation mode as well as by assignment of the operation device 0.