Block-by-block synchronization (default synchronization)
Field of technology functions with block-by-block synchronization | |
Description | Field of M/H/S/T technology functions with block-by-block synchronization. Technology functions are saved contiguously in this field. |
Information flow | CNC -> PLC |
ST path | pMC[channel_idx]^.addr^.ATechnoUnitChannel_Std[]tech_unit_idx |
Data type | ARRAY [1..HLI_MaxTechnoUnitsChStdSync] OF TechnoUnitChannel |
Access | PLC reads |
Characteristics |
|
Number of technology functions with block-by-block synchronization | |
Description | Number of entries in field ATechnoUnitChannel_Std ( = number of M functions to be acknowledged in this block) |
Information flow | CNC -> PLC |
ST path | pMC[channel_idx]^.addr^.W_UsedUnitsStdSync |
Data type | UINT |
Value range | [0, HLI_MaxTechnoUnitsChStdSync] |