ID-range 40000-40249

40001

Axis specific MC error.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40002

Axes group specific MC error.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40003

Platform specific MC error.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40004

Copying of version string from HLI into PLC's string variable failed.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40005

Different size of axis or channel specific HLI section of PLC and MC.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40006

Different HLI version string of PLC and MC.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40007

Checking of HLI version string impossible, because interface is occupied.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40008

Error occured while copying PLC's version string to HLI.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40009

Can't acknowledge check of PLC's HLI version string.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40010

Not defined state of the state machine of a FB.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40011

CU mc_check_plc_version: state variable is FALSE.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40012

MC doesn't run.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40013

MC isn't started already.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40014

Pointer to platform specific HLI section is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40015

Version string of HLI of MC and of PLC are different.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40016

HLI of MC and PLC has different specification.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40017

Axis specifc HLI section of MC and PLC differ concerning the amount of bytes.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40018

Channel specifc HLI section of MC and PLC differ concerning the amount of bytes.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40019

Pointer to structure containing information about the HLI specification is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40020

Number of detected axes differ from configured axes.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40021

Number of detected channels differ from configured channels.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40030

Pointer to HLI channel interface is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40031

Pointer to HLI axis interface is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40032

Axis is not configured to be used as motion axis.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40033

Registering at HLI control units failed.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40034

MC doesn't run cyclic already.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40035

MC hasn't finished the startup phase already.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40036

While initialising MCP a reference is detected, that references to a HLI interface that isn't used.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40037

Pointer to platform specific HLI section is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40038

Axis reference: addresses a HLI section that exceeds HLI definition.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40039

Axis reference: addressed HLI section doesn't exist.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40040

Axes group reference: addresses a HLI section that exceeds HLI definition.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40041

Axes group reference: addressed HLI section doesn't exist.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40042

Pointer to table manager memory is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40043

Pointer to named shared memory identified by PLCIO_INTF_SHM_NAME is 0.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40044

FB error: MCV_TRACE; got new trace command, but trace runs already.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40045

FB error: MCV_TRACE; writing to file is impossible.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40046

FB error: axis techno unit of that number isn't available.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40047

FB error: axes group techno unit of that number isn't available.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40048

HLI HMI: addresses a HLI section that exceeds HLI definition.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40049

HLI HMI: addressed HLI section doesn't exist.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40050

obsolete.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40051

No drive with SERCOS interface within all axis specific interfaces.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40052

Value of SERCOS phase exceeds range 0..4.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40053

Error occured while setting or commanding SERCOS phase.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40054

FB error: MCV_PartTracker.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40055

FB error: MCV_PartTracker; maximal number of tracked parts exceed number of administrated parts.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40056

FB error: MCV_PartTracker; no more parts can be stored within part administration

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40057

Error while reading sercos ident.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40058

Error while writing sercos ident.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40059

Error occured while setting or getting SERCOS ident

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40060

Index of input station exceeds value of global constant PLCIO_STATIONS_OF_BUS_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40061

Index of input slot exceeds value of global constant PLCIO_SLOTS_OF_STATION_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40062

Index of input data exceeds value of global constant PLCIO_DATA_OF_SLOTS_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40063

Index of output station exceeds value of global constant PLCIO_STATIONS_OF_BUS_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40064

Index of output slot exceeds value of global constant PLCIO_SLOTS_OF_STATION_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40065

Index of output data exceeds value of global constant PLCIO_DATA_OF_SLOTS_MAXIDX

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40066

FB error: MCV_AddCmdValues; value at input "Mode" is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40067

FB error: MCV_RedSpeedZone; value at input "ZoneNr" is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40068

FB error: MCV_DriveWord; value at input "DriveWordNr" is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40069

FB error: MCV_Mode; value at input "ModeNr" is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40070

FB error: MCV_GrpRedSpeedZone: value at input "ZoneNr" is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40071

FB error, KW: error id 1 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40072

FB error, KW: error id 2 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40073

FB error, KW: error id 3 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40074

FB error, KW: error id 4 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40075

FB error, KW: error id 5 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40076

FB error, KW: error id 6 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40077

FB error, KW: error id 7 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40078

FB error, KW: error id 8 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40079

FB error, KW: error id 9 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40080

FB error, KW: error id 10 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40081

FB error, KW: error id 11 of FB STR_TO_BUF.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40082

FB error: STRING_TO_BUF; copying of IEC string to buffer failed.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40083

FB error: BUF_TO_STRING; copying buffer to a IEC string failed.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40084

FB error, KW: STR_TO_BUF; returns unknown error id.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40085

FB error: MCV_MC_GetParamType; assigned empty string to input "Param".

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40086

FB error: Platform specific control unit can't take order.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40087

FB error: Axis specific control unit can't take order.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40088

FB error: Channel specific control unit can't take order.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40089

FB error: Value that classifies the axis type is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40090

FB error: Value that classifies the type of value is invalid.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40091

FB error: Searched axis at HLI by logical axis number, but didn't find such an axis.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

40092

FB error: Searched axis within axis references by logical number, but didn't find such an axis.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-