Measurement type (P-CHAN-00057)

Seven different measurement types are available. With this element, the desired measurement type can be set.

Variable name

Type

Permitted range

Dimension

messtyp

UNS16

1, 2, 3, 4, 5, 6, 7

----

Value

Significance

1

Measurement travel with at least one axis,

Measurement feed programmable through F-Word.

2

Measurement travel with exactly one axis.

Measurement feed is specified in the axis data list.

3

Measurement travel with at least one axis,

Measurement feed programmable through F-Word,

optionally further traverse up to the destination point.

4

Measurement travel only with the maximum of 3 main axes,

Measurement feed programmable through F-Word.

5

Interruptible measurement travel with at least one axis,

Measurement feed programmable through F-Word.

6

Interruptible measurement travel with at least one SERCOS-Axis,

Measurement feed programmable through F-Word.

7

Measurement travel by moving on a fixed stop with at least one axis,

Measurement feed programmable through F-Word.

Measurement type (P-CHAN-00057) 1:

The different measurement types 1-6 are also described in [PROG].

EXAMPLE: Selection of measurement type 3 for a measurement travel with two axes and subsequent further traverse up to the programmed destination point.

Extract from channel parameters list:

# Setting of measurement type
messtyp                   3