Example for a compensation list

# ****************************************

# Axis compensation data for Z-axis

# ****************************************

kopf.achs_nr 1

kopf.log_achs_name X

kw.crosscomp2.interval 100000 /* 10 mm */

kw.crosscomp2.last_index_master1 100

kw.crosscomp2.last_index_master2 100

kw.crosscomp2.start_position_master1 -400000 /* -40 mm */

kw.crosscomp2.start_position_master2 -700000 /* -70 mm */

kw.crosscomp2.unit 1 /* 0,1 my */

kw.crosscomp2.n_cycles 10

kw.crosscomp2.master1_ax_nr 1

kw.crosscomp2.master2_ax_nr 2

kw.crosscomp2.table[ 0][ 0].correction -3

kw.crosscomp2.table[ 0][ 1].correction -1

kw.crosscomp2.table[ 0][ 2].correction 4

kw.crosscomp2.table[ 0][ 3].correction 9

kw.crosscomp2.table[ 0][ 4].correction 13

kw.crosscomp2.table[ 0][ 5].correction 17

kw.crosscomp2.table[ 0][ 6].correction 42

kw.crosscomp2.table[ 0][ 7].correction 53

...

kw.crosscomp2.table[100][ 90].correction 82

kw.crosscomp2.table[100][ 91].correction 77

kw.crosscomp2.table[100][ 92].correction 68

kw.crosscomp2.table[100][ 93].correction 63

kw.crosscomp2.table[100][ 94].correction 61

kw.crosscomp2.table[100][ 95].correction 59

kw.crosscomp2.table[100][ 96].correction 57

kw.crosscomp2.table[100][ 97].correction 52

kw.crosscomp2.table[100][ 98].correction 56

kw.crosscomp2.table[100][ 99].correction 58

kw.crosscomp2.table[100][100].correction 49

End