ReadOnlyRpcMethodCollection Class

Read only RpcMethodCollection

Inheritance Hierarchy

System.Object
  System.Collections.ObjectModel.ReadOnlyCollection.IRpcMethod.
    TwinCAT.TypeSystem.ReadOnlyRpcMethodCollection
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class ReadOnlyRpcMethodCollection : ReadOnlyCollection<IRpcMethod>

VB

Public Class ReadOnlyRpcMethodCollection
    Inherits ReadOnlyCollection(Of IRpcMethod)

The ReadOnlyRpcMethodCollection type exposes the following members.

Properties

 

Name

Description

Count

Gets the number of elements contained in the ReadOnlyCollection.T. instance. (Inherited from ReadOnlyCollection.IRpcMethod..)

Item.Int32.

Gets the element at the specified index. (Inherited from ReadOnlyCollection.IRpcMethod..)

Item.String.

Gets the IRpcMethod with the specified method name.

Items

Returns the IList.T. that the ReadOnlyCollection.T. wraps. (Inherited from ReadOnlyCollection.IRpcMethod..)

Methods

 

Name

Description

Contains(String)

Determines whether this collection contains the specified method name.

Contains(T)

Determines whether an element is in the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

CopyTo

Copies the entire ReadOnlyCollection.T. to a compatible one-dimensional Array, starting at the specified index of the target array. (Inherited from ReadOnlyCollection.IRpcMethod..)

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

GetEnumerator

Returns an enumerator that iterates through the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

GetHashCode

Serves as the default hash function. (Inherited from Object.)

GetType

Gets the Type of the current instance. (Inherited from Object.)

IndexOf

Searches for the specified object and returns the zero-based index of the first occurrence within the entire ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

ToString

Returns a string that represents the current object. (Inherited from Object.)

TryGetMethod(Int32, IRpcMethod.)

Tries to get the specified method.

TryGetMethod(String, IRpcMethod.)

Tries to get the specified method.

Reference

TwinCAT.TypeSystem Namespace