IValueRawSymbol Interface

Interface IValueRawSymbol

Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public interface IValueRawSymbol : ISymbol, 
    IAttributedInstance, IInstance, IBitSize

VB

Public Interface IValueRawSymbol
    Inherits ISymbol, IAttributedInstance, IInstance, IBitSize

The IValueRawSymbol type exposes the following members.

Properties

 

Name

Description

Attributes

Gets the Type Attributes. (Inherited from IAttributedInstance.)

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

Category

Gets the Symbol/Datatype Category (Inherited from ISymbol.)

Comment

Gets the comment of the IInstance (Inherited from IInstance.)

DataType

Gets the IDataType of the IInstance. (Inherited from IInstance.)

HasValue

Gets a value indicating whether this IValueSymbol has a value.

InstanceName

Gets the name of the instance (without periods (.) (Inherited from IInstance.)

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from IInstance.)

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

IsContainerType

Gets a value indicating whether this Symbol is a container type. (Inherited from ISymbol.)

IsPersistent

Gets a value indicating whether this ISymbol is persistent. (Inherited from ISymbol.)

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from IInstance.)

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type. (Inherited from ISymbol.)

IsReadOnly

Gets a value indicating whether this ISymbol is read only. (Inherited from ISymbol.)

IsRecursive

Gets a value indicating whether this instance is recursive. (Inherited from ISymbol.)

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from IInstance.)

IsStatic

Gets a value indicating whether this IInstance is static. (Inherited from IInstance.)

Parent

Gets the parent Symbol (Inherited from ISymbol.)

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

SubSymbols

Gets the SubSymbols of the ISymbol (Inherited from ISymbol.)

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from IInstance.)

Methods

 

Name

Description

ReadRawValue.

Reads the raw value of the IValueSymbol (Ads Read / Write)

ReadRawValue(Int32)

Reads the raw value of the IValueSymbol (Ads Read / Write)

WriteRawValue(.Byte.)

Writes the raw value of the IValueSymbol (Ads Read / Write)

WriteRawValue(.Byte., Int32)

Writes the raw value of the IValueSymbol (Ads Read / Write)

Events

 

Name

Description

RawValueChanged

Occurs when the RawValue of the IValueSymbol has changed.

Reference

TwinCAT.TypeSystem Namespace