ISymbolCollection Interface
Interface ISymbolCollection
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 4.3.0.0
Syntax
C#
public interface ISymbolCollection : ISymbolCollection<ISymbol>,
IInstanceCollection<ISymbol>, IList<ISymbol>, ICollection<ISymbol>,
IEnumerable<ISymbol>, IEnumerable
VB
Public Interface ISymbolCollection
Inherits ISymbolCollection(Of ISymbol), IInstanceCollection(Of ISymbol),
IList(Of ISymbol), ICollection(Of ISymbol), IEnumerable(Of ISymbol),
IEnumerable
The ISymbolCollection type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets the number of elements contained in the ICollection.T.. (Inherited from ICollection.ISymbol..) | |
|
|
Gets a value indicating whether the ICollection.T. is read-only. (Inherited from ICollection.ISymbol..) | |
|
|
Gets or sets the element at the specified index. (Inherited from IList.ISymbol..) | |
|
|
Gets the IInstance with the specified instance path. (Inherited from IInstanceCollection.T..) | |
|
|
Gets the InstanceCollectionMode. (Inherited from IInstanceCollection.T..) |
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Adds an item to the ICollection.T.. (Inherited from ICollection.ISymbol..) | |
|
|
Removes all items from the ICollection.T.. (Inherited from ICollection.ISymbol..) | |
|
|
Determines whether this collection contains an instance with the specified instance path. (Inherited from IInstanceCollection.T..) | |
|
|
Determines whether the ICollection.T. contains a specific value. (Inherited from ICollection.ISymbol..) | |
|
|
Determines whether this collection contains an instance with the specified instance name. (Inherited from IInstanceCollection.T..) | |
|
|
Copies the elements of the ICollection.T. to an Array, starting at a particular Array index. (Inherited from ICollection.ISymbol..) | |
|
|
Returns an enumerator that iterates through the collection. (Inherited from IEnumerable.ISymbol..) | |
|
|
Gets the IInstanceby instance path. (Inherited from IInstanceCollection.T..) | |
|
|
Gets the IInstance by instance name. (Inherited from IInstanceCollection.T..) | |
|
|
Determines the index of a specific item in the IList.T.. (Inherited from IList.ISymbol..) | |
|
|
Inserts an item to the IList.T. at the specified index. (Inherited from IList.ISymbol..) | |
|
|
Removes the first occurrence of a specific object from the ICollection.T.. (Inherited from ICollection.ISymbol..) | |
|
|
Removes the IList.T. item at the specified index. (Inherited from IList.ISymbol..) | |
|
|
Tries to get the specified instance. (Inherited from IInstanceCollection.T..) | |
|
|
Tries to get the specified instance by name. (Inherited from IInstanceCollection.T..) |