DynamicSymbolsContainer Class
Dynamic (Expandable) Symbols collection.
Inheritance Hierarchy
System.Object
System.Dynamic.DynamicObject
TwinCAT.TypeSystem.DynamicSymbolsContainer
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 4.3.0.0
Syntax
C#
public sealed class DynamicSymbolsContainer : DynamicObject,
IEnumerable<ISymbol>, IEnumerable
VB
Public NotInheritable Class DynamicSymbolsContainer
Inherits DynamicObject
Implements IEnumerable(Of ISymbol), IEnumerable
The DynamicSymbolsContainer type exposes the following members.
Constructors
|
|
Name |
Description |
|---|---|---|
|
|
Initializes a new instance of the DynamicSymbolsContainer class (for internal use only) |
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Determines whether the specified object is equal to the current object. (Inherited from Object.) | |
|
|
Returns the enumeration of all dynamic member names. (Overrides DynamicObject.GetDynamicMemberNames..) | |
|
|
Gets the enumerator. | |
|
|
Serves as the default hash function. (Inherited from Object.) | |
|
|
Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.) | |
|
|
Gets the Type of the current instance. (Inherited from Object.) | |
|
|
Returns a string that represents the current object. (Inherited from Object.) | |
|
|
Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.) | |
|
|
Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Inherited from DynamicObject.) | |
|
|
Tries to get the IInstance. of the specified path. | |
|
|
Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Overrides DynamicObject.TryGetMember(GetMemberBinder, Object.).) | |
|
|
Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Inherited from DynamicObject.) | |
|
|
Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.) |
Remarks
The DynamicSymbolsContainer collection adds dynamically its child Symbols as Members (for access like "Main.Symbol")