DynamicRpcStructInstance Class
Dynamic struct instance with RPC Methods.
Inheritance Hierarchy
System.Object
System.Dynamic.DynamicObject
TwinCAT.TypeSystem.DynamicSymbol
TwinCAT.TypeSystem.DynamicStructInstance
TwinCAT.TypeSystem.DynamicRpcStructInstance
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 4.3.0.0
Syntax
C#
public sealed class DynamicRpcStructInstance : DynamicStructInstance,
IRpcStructInstance, IStructInstance, ISymbol, IAttributedInstance, IInstance,
IBitSize, IRpcCallableInstance
VB
Public NotInheritable Class DynamicRpcStructInstance
Inherits DynamicStructInstance
Implements IRpcStructInstance, IStructInstance, ISymbol, IAttributedInstance,
IInstance, IBitSize, IRpcCallableInstance
The DynamicRpcStructInstance type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Inner symbol object wrapped by this DynamicSymbol (Inherited from DynamicSymbol.) | |
|
|
Gets the access rights. (Inherited from DynamicSymbol.) | |
|
|
Gets the Symbol Attributes (Inherited from DynamicSymbol.) | |
|
|
Gets the size of the IDataType in bits. (Inherited from DynamicSymbol.) | |
|
|
Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from DynamicSymbol.) | |
|
|
Gets the category. (Inherited from DynamicSymbol.) | |
|
|
Gets the comment of the IInstance (Inherited from DynamicSymbol.) | |
|
|
Gets the connection bound to this DynamicSymbol (Inherited from DynamicSymbol.) | |
|
|
Gets the context mask. (Inherited from DynamicSymbol.) | |
|
|
Gets the IDataType of the IInstance. (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this instance has RPC methods (Inherited from DynamicStructInstance.) | |
|
|
Gets a value indicating whether this instance has value (only the non VirtualInstances, what means the Symbols with locations). (Inherited from DynamicSymbol.) | |
|
|
Gets the name of the instance (without periods (.) (Inherited from DynamicSymbol.) | |
|
|
Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from DynamicSymbol.) | |
|
|
Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this Symbol is acontainer type. (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this ISymbol is persistent. (Inherited from DynamicSymbol.) | |
|
|
Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this instance is a primitive type. (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this ISymbol is read only. (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this instance is recursive. (Inherited from DynamicSymbol.) | |
|
|
Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from DynamicSymbol.) | |
|
|
Gets a value indicating whether this instance is static. (Inherited from DynamicSymbol.) | |
|
|
Gets the member instances of the Struct Instance. (Inherited from DynamicStructInstance.) | |
|
|
Gets the normalized instance name (fixed name for dynamic property access that doesn't contain invalid characters), (Inherited from DynamicSymbol.) | |
|
|
Gets the notification settings. (Inherited from DynamicSymbol.) | |
|
|
Gets the parent Symbol (Inherited from DynamicSymbol.) | |
|
|
Gets the Method descriptions for the IRpcCallableType | |
|
|
Gets the size of the IInstance in bytes. (Inherited from DynamicSymbol.) | |
|
|
Gets the SubSymbols of the ISymbol (Inherited from DynamicSymbol.) | |
|
|
Gets the name of the DataType that is used for this IInstance. (Inherited from DynamicSymbol.) |
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Equals (Inherited from DynamicSymbol.) | |
|
|
Gets the dynamic member names. (Overrides DynamicStructInstance.GetDynamicMemberNames..) | |
|
|
Gets the HashCode of the Address (Inherited from DynamicSymbol.) | |
|
|
Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.) | |
|
|
Gets the Type of the current instance. (Inherited from Object.) | |
|
|
Invokes the specified method. | |
|
|
Reads the value of this Value into a new created instance of the managed type (Inherited from DynamicSymbol.) | |
|
|
Reads the Symbols raw value (Inherited from DynamicSymbol.) | |
|
|
Reads the Symbols raw value (Inherited from DynamicSymbol.) | |
|
|
Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.) | |
|
|
Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.) | |
|
|
Returns a String that represents this instance. (Inherited from DynamicSymbol.) | |
|
|
Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.) | |
|
|
Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Overrides DynamicStructInstance.TryGetMember(GetMemberBinder, Object.).) | |
|
|
Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Overrides DynamicObject.TryInvokeMember(InvokeMemberBinder, .Object., Object.).) | |
|
|
Tries to invoke the specified method. | |
|
|
Tries to invoke the specified method. | |
|
|
Reads the Value of the IValueSymbol (Inherited from DynamicSymbol.) | |
|
|
Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Inherited from DynamicObject.) | |
|
|
Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Overrides DynamicStructInstance.TrySetMember(SetMemberBinder, Object).) | |
|
|
Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.) | |
|
|
Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.) | |
|
|
Reads the value of this Value into the specified managed value. (Inherited from DynamicSymbol.) | |
|
|
Writes the value represented by the managed value to this Value (Inherited from DynamicSymbol.) | |
|
|
Writes the Symbol raw Value (Inherited from DynamicSymbol.) | |
|
|
Writes the Symbol raw Value (Inherited from DynamicSymbol.) | |
|
|
Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.) | |
|
|
Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.) |
Events
|
|
Name |
Description |
|---|---|---|
|
|
Occurs when the RawValue of the IValueSymbol has changed. (Inherited from DynamicSymbol.) | |
|
|
Occurs when the (Primitive) value of the IValueSymbol has changed. (Inherited from DynamicSymbol.) |