RpcStructType Class

StructType which is callable by RPC Methods.

Inheritance Hierarchy

System.Object
  TwinCAT.Ads.TypeSystem.DataType
    TwinCAT.Ads.TypeSystem.StructType
      TwinCAT.Ads.TypeSystem.RpcStructType
Namespace:  TwinCAT.Ads.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public sealed class RpcStructType : StructType, 
    IRpcCallableType

VB

Public NotInheritable Class RpcStructType
    Inherits StructType
    Implements IRpcCallableType

The RpcStructType type exposes the following members.

Properties

 

Name

Description

AllMembers

Gets all members (down the derivation hierarchy) (Inherited from StructType.)

Attributes

Gets the attributes of the IDataType (Inherited from DataType.)

BaseType

Gets the structs Base Type (Null if not derived). (Inherited from StructType.)

BaseTypeName

Gets the the Name of the Base class (if derived) (Inherited from StructType.)

BitSize

Gets the size of the DataType in bits. (Inherited from DataType.)

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from DataType.)

Category

Gets the Data Type category (Inherited from DataType.)

Comment

Gets the comment. (Inherited from DataType.)

FullName

Gets the full name of the IDataType (Namespace + Name) (Inherited from DataType.)

HasRpcMethods

Gets a value indicating whether this instance has RPC Methods. (Overrides StructType.HasRpcMethods.)

Id

Gets the ID of the DataType (Inherited from DataType.)

IsBitType

Gets a value indicating whether this IDataType is a bit mapping Type (Inherited from DataType.)

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from DataType.)

IsContainer

Gets a value indicating whether this IDataType is a container type (Inherited from DataType.)

IsDerived

Gets a value indicating whether this instance is derived. (Inherited from StructType.)

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Inherited from DataType.)

IsPrimitive

Gets a value indicating whether this IDataType is primitive (Inherited from DataType.)

IsReference

Gets a value indicating whether this IDataType is a reference type (Inherited from DataType.)

ManagedType

Gets the corresponding .NET Type if attached. (Inherited from DataType.)

Members

Gets a read only collection of the Members of the IStructType. (Inherited from StructType.)

Name

Gets the name of the Data Type (without namespace) (Inherited from DataType.)

Namespace

Gets the namespace string within the IDataType exists. (Inherited from DataType.)

RpcMethods

Gets the Method descriptions for the IRpcCallableType

Size

Gets the Size of the DataType in Bytes (Inherited from DataType.)

Methods

 

Name

Description

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

GetHashCode

Serves as the default hash function. (Inherited from Object.)

GetType

Gets the Type of the current instance. (Inherited from Object.)

ToString

Returns a String that represents this instance. (Inherited from DataType.)

Reference

TwinCAT.Ads.TypeSystem Namespace