ValueSymbolExtensions.WhenValueChanged Method (IAdsConnection, IEnumerable.ISymbol.)
Observable sequence of Values driven by ADS Notifications on the specified symbol.
Namespace: TwinCAT.Ads.Reactive
Assembly: TwinCAT.Ads.Reactive (in
TwinCAT.Ads.Reactive.dll) Version: 4.3.0.0 (4.3.7.0)
Syntax
C#
public static IObservable<Object> WhenValueChanged(
this IAdsConnection connection,
IEnumerable<ISymbol> symbols
)
VB
<ExtensionAttribute>
Public Shared Function WhenValueChanged (
connection As IAdsConnection,
symbols As IEnumerable(Of ISymbol)
) As IObservable(Of Object)
Parameters
|
connection |
Type: TwinCAT.Ads.IAdsConnection |
|
symbols |
Type: System.Collections.Generic.IEnumerable.ISymbol. |
Return Value
Type: IObservable.Object.
IObservable<ValueChangedArgs>.
Usage Note
In Visual Basic and C#, you can call this method as an instance method on any object of type IAdsConnection. When you use instance method syntax to call this method, omit the first parameter. For more information, see Extension Methods (Visual Basic) or Extension Methods (C# Programming Guide).
Observe changing ADS Symbols (ADS Notifications)
// To Test the Observer run a project on the local PLC System (Port 851)
using (TcAdsClient client = new TcAdsClient())
{
// Connect to target
client.Connect(new AmsAddress(AmsNetId.Local, 851));
// Create Symbol information
var symbolLoader = SymbolLoaderFactory.Create(client, SymbolLoaderSettings.Default);
IValueSymbol cycleCount = (IValueSymbol)symbolLoader.Symbols["TwinCAT_SystemInfoVarList._TaskInfo.CycleCount"]; // UShort Type
IValueSymbol lastExecTime = (IValueSymbol)symbolLoader.Symbols["TwinCAT_SystemInfoVarList._TaskInfo.LastExecTime"]; // UInt Type
SymbolCollection symbols = new SymbolCollection();
symbols.Add(cycleCount);
symbols.Add(lastExecTime);
// Reactive Notification Handler
var valueObserver = Observer.Create<object>(val =>
{
Console.WriteLine(string.Format("Instance: {0}, Value: {1}", cycleCount.InstancePath, val.ToString()));
}
);
cycleCount.NotificationSettings = new NotificationSettings(AdsTransMode.OnChange,500,5000); // optional: Change NotificationSettings on Symbol
// Turning ADS Notifications into sequences of Value Objects (Taking 20 Values)
// and subscribe to them.
IDisposable subscription = client.WhenValueChanged(symbols).Take(20).Subscribe(valueObserver);
Console.ReadKey(); // Wait for Key press
subscription.Dispose(); // Dispose the Subscription
}
Examples
The following sample shows how to observe Value changed Notifications with the reactive ValueSymbolExtensions from an DynamicSymbol.
Observe a single changing ADS Symbol (ADS Notifications) with the dynamic language runtime (.NET DLR)
// To Test the Observer run a project on the local PLC System (Port 851)
using (TcAdsClient client = new TcAdsClient())
{
// Connect to target
client.Connect(new AmsAddress(AmsNetId.Local, 851));
// Create Symbol information
var symbolLoader = SymbolLoaderFactory.Create(client, SymbolLoaderSettings.Default);
IValueSymbol cycleCount = (IValueSymbol)symbolLoader.Symbols["TwinCAT_SystemInfoVarList._TaskInfo[1].CycleCount"];
// Reactive Notification Handler
var valueObserver = Observer.Create<object>(val =>
{
Console.WriteLine(string.Format("Instance: {0}, Value: {1}", cycleCount.InstancePath, val.ToString()));
}
);
cycleCount.NotificationSettings = new NotificationSettings(AdsTransMode.OnChange, 500, 5000); // optional: Change NotificationSettings on Symbol
// Turning ADS Notifications into sequences of Value Objects (Taking 20 Values)
// and subscribe to them.
IDisposable subscription = cycleCount.WhenValueChanged().Take(20).Subscribe(valueObserver);
Console.ReadKey(); // Wait for Key press
subscription.Dispose(); // Dispose the Subscription
}