AdsInvalidNotificationException Class
This AdsInvalidNotificationException is created if the length of the notification data is 0. This indicates that the notification handle is not valid any more. This exception is passed to the AdsNotificationErrorEvent.
Inheritance Hierarchy
System.Object
System.Exception
System.ApplicationException
TwinCAT.Ads.AdsException
TwinCAT.Ads.AdsInvalidNotificationException
Namespace: TwinCAT.Ads
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 4.3.0.0
Syntax
C#
[SerializableAttribute]
public sealed class AdsInvalidNotificationException : AdsException
VB
<SerializableAttribute>
Public NotInheritable Class AdsInvalidNotificationException
Inherits AdsException
The AdsInvalidNotificationException type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets a collection of key/value pairs that provide additional user-defined information about the exception. (Inherited from Exception.) | |
|
|
Handle of the notification. | |
|
|
Gets or sets a link to the help file associated with this exception. (Inherited from Exception.) | |
|
|
Gets or sets HRESULT, a coded numerical value that is assigned to a specific exception. (Inherited from Exception.) | |
|
|
Gets the Exception instance that caused the current exception. (Inherited from Exception.) | |
|
|
Gets a message that describes the current exception. (Inherited from Exception.) | |
|
|
Gets or sets the name of the application or the object that causes the error. (Inherited from Exception.) | |
|
|
Gets a string representation of the immediate frames on the call stack. (Inherited from Exception.) | |
|
|
Gets the method that throws the current exception. (Inherited from Exception.) | |
|
|
Gets the Time stamp as long |
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Determines whether the specified object is equal to the current object. (Inherited from Object.) | |
|
|
When overridden in a derived class, returns the Exception that is the root cause of one or more subsequent exceptions. (Inherited from Exception.) | |
|
|
Serves as the default hash function. (Inherited from Object.) | |
|
|
When overridden in a derived class, sets the SerializationInfo with information about the exception. (Overrides Exception.GetObjectData(SerializationInfo, StreamingContext).) | |
|
|
Gets the runtime type of the current instance. (Inherited from Exception.) | |
|
|
Creates and returns a string representation of the current exception. (Inherited from Exception.) |