Read PLC variable declaration
Download
Language / IDE | Unpack the example program |
---|---|
Visual C# | |
Visual Basic (for .NET Framework) | |
Delphi Prism (Embarcadero Prism XE2, Oxygene for .NET) | |
Delphi for .NET (Borland Developer Studio 2006) |
Task
All variables that are declared in the PLC should be displayed in a tree view.
Description
In the Form1_Load method an instance of the TcAdsSymbolInfoLoader is created with a call to TcAdsClient.CreateSymbolInfoLoader. This class is responsible for loading the symbol information from the PLC. By clicking the Load Symbols button the symbols are loaded by means of the TcAdsSymbolInfoLoader.GetFirstSymbol method. This method returns the first loaded symbol as a TcAdsSymbolInfo object. The methods TcAdsSymbolInfo.NextSymbol und TcAdsSymbolInfo.FirstSubSymbol are used to iterate over the symbols and to display the symbols hierarchically in the tree view. If the check box flat is checked, the symbols are displayed in a flat list. In this case foreach is used to enumerate over the symbols loaded by the TcAdsSymbolInfoLoader object. This includes the sub symbols.
By selecting a tree view item, the edit boxes are filled with the symbol information. Additionally the value of the variable is read with the help of TcAdClient.ReadSymbol and is displayed in the value edit box. To write a value to a variable one has to click the Write Value button, which leads to a call of TcAdsCient.WriteSymbol.
To read the symbol information for a specific variable, one can either click the Read Symbol Info or the Find Symbol button. In the first case the method TcAdsClient.ReadSymbolInfo is called. This leads to an ADS call, to load the information for this symbol from the PLC. In the second case the method TcAdsSymbolInfoLoader.FindSymbol is called, to search for the symbol in the list of the previous loaded symbols. If no symbols have been loaded before, all symbols are loaded from the PLC.
C# Programm
using System;
using System.Drawing;
using System.Collections;
using System.ComponentModel;
using System.Windows.Forms;
using System.Data;
using System.IO;
using TwinCAT.Ads;
namespace Sample06
{
/// <summary>
/// Summary description for Form1.
/// </summary>
public class Form1 : System.Windows.Forms.Form
{
private System.Windows.Forms.TreeView treeViewSymbols;
private System.Windows.Forms.GroupBox groupBox1;
private System.Windows.Forms.Button btnLoad;
private System.Windows.Forms.Label label3;
private System.Windows.Forms.TextBox tbDatatype;
private System.Windows.Forms.Label label2;
private System.Windows.Forms.TextBox tbIndexGroup;
private System.Windows.Forms.Label label1;
private System.Windows.Forms.TextBox tbIndexOffset;
private System.Windows.Forms.Button btnFindSymbol;
private System.Windows.Forms.Button btnReadSymbolInfo;
private System.Windows.Forms.GroupBox groupBox2;
private System.Windows.Forms.Label label4;
private System.Windows.Forms.Label label5;
private System.Windows.Forms.TextBox tbDatatypeId;
private System.Windows.Forms.Label label6;
private System.Windows.Forms.TextBox tbValue;
/// <summary>
/// Required designer variable.
/// </summary>
private System.ComponentModel.Container components = null;
private TcAdsClient adsClient;
private System.Windows.Forms.TextBox tbSymbolname;
private System.Windows.Forms.Label label9;
private System.Windows.Forms.TextBox tbSize;
private System.Windows.Forms.Button btnWrite;
private TcAdsSymbolInfoLoader symbolLoader;
private System.Windows.Forms.TextBox tbName;
private System.Windows.Forms.Label label7;
private System.Windows.Forms.CheckBox cbFlat;
private ITcAdsSymbol currentSymbol = null;
public Form1()
{
InitializeComponent();
}
/// <summary>
/// Clean up any resources being used.
/// </summary>
protected override void Dispose( bool disposing )
{
if( disposing )
{
if (components != null)
{
components.Dispose();
}
}
base.Dispose( disposing );
}
#region Windows Form Designer generated code
...
#endregion
/// <summary>
/// The main entry point for the application.
/// </summary>
[STAThread]
static void Main()
{
Application.Run(new Form1());
}
private void Form1_Load(object sender, System.EventArgs e)
{
try
{
adsClient = new TcAdsClient();
// Connect to local PLC - Runtime 1 - TwinCAT2 Port=801, TwinCAT3 Port=851
adsClient.Connect(801);
symbolLoader = adsClient.CreateSymbolInfoLoader();
}
catch(Exception err)
{
MessageBox.Show(err.Message);
}
}
private void btnLoad_Click(object sender, System.EventArgs e)
{
treeViewSymbols.Nodes.Clear();
if( !cbFlat.Checked )
{
TcAdsSymbolInfo symbol = symbolLoader.GetFirstSymbol(true);
while( symbol != null )
{
treeViewSymbols.Nodes.Add(CreateNewNode(symbol));
symbol = symbol.NextSymbol;
}
}
else
{
foreach( TcAdsSymbolInfo symbol in symbolLoader )
{
TreeNode node = new TreeNode(symbol.Name);
node.Tag = symbol;
treeViewSymbols.Nodes.Add(node);
}
}
}
private void btnReadSymbolInfo_Click(object sender, System.EventArgs e)
{
try
{
ITcAdsSymbol symbol = adsClient.ReadSymbolInfo(tbSymbolname.Text);
if( symbol == null)
{
MessageBox.Show("Symbol " + tbSymbolname.Text + " not found");
return;
}
SetSymbolInfo(symbol);
}
catch( Exception err )
{
MessageBox.Show(err.Message);
}
}
private void btnFindSymbol_Click(object sender, System.EventArgs e)
{
try
{
ITcAdsSymbol symbol = symbolLoader.FindSymbol(tbSymbolname.Text);
if( symbol == null)
{
MessageBox.Show("Symbol " + tbSymbolname.Text + " not found");
return;
}
SetSymbolInfo(symbol);
}
catch( Exception err )
{
MessageBox.Show(err.Message);
}
}
private void btnWrite_Click(object sender, System.EventArgs e)
{
try
{
if( currentSymbol != null )
adsClient.WriteSymbol(currentSymbol, tbValue.Text);
}
catch(Exception err)
{
MessageBox.Show("Unable to write Value. " + err.Message);
}
}
private void treeViewSymbols_AfterSelect(object sender, System.Windows.Forms.TreeViewEventArgs e)
{
if( e.Node.Text.Length > 0 )
{
if( e.Node.Tag is TcAdsSymbolInfo )
{
SetSymbolInfo((ITcAdsSymbol)e.Node.Tag);
}
}
}
private TreeNode CreateNewNode(TcAdsSymbolInfo symbol)
{
TreeNode node = new TreeNode(symbol.Name);
node.Tag = symbol;
TcAdsSymbolInfo subSymbol = symbol.FirstSubSymbol;
while( subSymbol != null )
{
node.Nodes.Add(CreateNewNode(subSymbol));
subSymbol = subSymbol.NextSymbol;
}
return node;
}
private void SetSymbolInfo(ITcAdsSymbol symbol)
{
currentSymbol = symbol;
tbName.Text = symbol.Name.ToString();
tbIndexGroup.Text = symbol.IndexGroup.ToString();
tbIndexOffset.Text = symbol.IndexOffset.ToString();
tbSize.Text = symbol.Size.ToString();
tbDatatype.Text = symbol.Type;
tbDatatypeId.Text = symbol.Datatype.ToString();
try
{
tbValue.Text = adsClient.ReadSymbol(symbol).ToString();
}
catch( AdsDatatypeNotSupportedException err )
{
tbValue.Text = err.Message;
}
catch(Exception err)
{
MessageBox.Show("Unable to read Symbol Info. " + err.Message);
}
}
}
}
PLC program
PROGRAM MAIN
VAR
REAL32_1 AT %MB0 : REAL; (* 1 *)
REAL32_2 AT %MB4 : REAL; (* 2 *)
REAL32_3 AT %MB8 : REAL; (* 3 *)
REAL32_4 AT %MB12: REAL; (* 4 *)
REAL32_5 AT %MB16: REAL; (* 5 *)
REAL64_1 AT %MB20 : LREAL; (* 6 *)
REAL64_2 AT %MB28 : LREAL; (* 7 *)
REAL64_3 AT %MB36 : LREAL; (* 8 *)
REAL64_4 AT %MB44 : LREAL; (* 9 *)
REAL64_5 AT %MB52 : LREAL; (* 10 *)
INT32_1 AT %MB60 : DINT; (* 11 *)
INT32_2 AT %MB64 : DINT; (* 12 *)
INT32_3 AT %MB68 : DINT; (* 13 *)
INT32_4 AT %MB72 : DINT; (* 14 *)
INT32_5 AT %MB76 : DINT; (* 15 *)
UINT32_1 AT %MB80 : UDINT; (* 16 *)
UINT32_2 AT %MB84 : UDINT; (* 17 *)
UINT32_3 AT %MB88 : UDINT; (* 18 *)
UINT32_4 AT %MB92 : UDINT; (* 19 *)
UINT32_5 AT %MB96 : UDINT; (* 20 *)
INT16_1 AT %MB100 : INT; (* 21 *)
INT16_2 AT %MB102 : INT; (* 22 *)
INT16_3 AT %MB104 : INT; (* 23 *)
INT16_4 AT %MB106 : INT; (* 24 *)
INT16_5 AT %MB108 : INT; (* 25 *)
UINT16_1 AT %MB110 : UINT; (* 26 *)
UINT16_2 AT %MB112 : UINT; (* 27 *)
UINT16_3 AT %MB114 : UINT; (* 28 *)
UINT16_4 AT %MB116 : UINT; (* 29 *)
UINT16_5 AT %MB118 : UINT; (* 30 *)
INT8_1 AT %MB120 : SINT; (* 31 *)
INT8_2 AT %MB121 : SINT; (* 32 *)
INT8_3 AT %MB122 : SINT; (* 33 *)
INT8_4 AT %MB123 : SINT; (* 34 *)
INT8_5 AT %MB124 : SINT; (* 35 *)
UINT8_1 AT %MB125 : USINT; (* 36 *)
UINT8_2 AT %MB126 : USINT; (* 37 *)
UINT8_3 AT %MB128 : USINT; (* 38 *)
UINT8_4 AT %MB129 : USINT; (* 39 *)
UINT8_5 AT %MB130 : USINT; (* 40 *)
BOOL_1 AT %MX131.0 : BOOL; (* 41 *)
BOOL_2 AT %MX131.1 : BOOL; (* 42 *)
BOOL_3 AT %MX131.2 : BOOL; (* 43 *)
BOOL_4 AT %MX131.3 : BOOL; (* 44 *)
BOOL_5 AT %MX131.4 : BOOL; (* 45 *)
ARRAY_1 : ARRAY[1 .. 10] OF SINT; (* 46 *)
ARRAY_2 : ARRAY[1 .. 10] OF INT; (* 47 *)
ARRAY_3 : ARRAY[1 .. 10] OF DINT; (* 48 *)
ARRAY_4 : ARRAY[1 .. 10] OF LREAL;(* 49 *)
ARRAY_5 : ARRAY[1 .. 10] OF BOOL; (* 50 *)
STRING_1 : STRING(20);
END_VAR