Transmitting a structure to the PLC with Delphi
Task
A structure is to be written into the PLC by the .NET application. The elements in the structure have different data types.
Description
The structure we want to write into the PLC:
TYPE PLCStruct
STRUCT
intVal : INT; (*Offset 0*)
dintVal : DINT; (*Offset 2*)
byteVal : SINT; (*Offset 6*)
lrealVal : LREAL;(*Offset 7*)
realVal : REAL; (*Offset 15 --> Total size 19 Bytes*)
END_STRUCT
END_TYPE
The AdsStream object is initialized with a size of 19 bytes in the write event method. This is equivalent to the size of the data type PLCStruct in the SPS. A BinaryWriter is used to write the data from the textboxes to the stream. After setting the stream position to 0 the individual fields are written to the stream. Finally, the total stream is written into the SPS with the help of TcAdsClient.Write.

Delphi Prism (Embarcadero Prism XE2, Oxygene for .NET) program
namespace Sample02;
interface
uses
System.Drawing,
System.Collections,
System.Collections.Generic,
System.Windows.Forms,
System.ComponentModel, System.IO, TwinCAT.Ads;
type
/// <summary>
/// Summary description for MainForm.
/// </summary>
MainForm = partial class(System.Windows.Forms.Form)
private
method btnWrite_Click(sender: System.Object; e: System.EventArgs);
method MainForm_Load(sender: System.Object; e: System.EventArgs);
method MainForm_FormClosing(sender: System.Object; e: System.Windows.Forms.FormClosingEventArgs);
tcClient : TcAdsClient;
hVar : Integer;
protected
method Dispose(disposing: Boolean); override;
public
// TYPE PLCStruct :
// STRUCT
// intVal : INT; 2 byte, signed integer
// dintVal : DINT; 4 byte, signed integer
// sintVal : SINT; 1 byte, signed integer
// lrealVal: LREAL; 8 byte, floating point value
// realVal : REAL; 4 byte, floating point value
// END_STRUCT
// END_TYPE
// Length of all PLC structure members = 19 byte (x86, byte alignment)
const MAX_ADSSTREAM_SIZE = 19;// SIZEOF(PLCStruct), Max. byte length of PLC structure
constructor;
end;
implementation
{$REGION Construction and Disposition}
constructor MainForm;
begin
//
// Required for Windows Form Designer support
//
InitializeComponent();
//
// TODO: Add any constructor code after InitializeComponent call
//
end;
method MainForm.Dispose(disposing: Boolean);
begin
if disposing then begin
if assigned(components) then
components.Dispose();
//
// TODO: Add custom disposition code here
//
end;
inherited Dispose(disposing);
end;
{$ENDREGION}
method MainForm.btnWrite_Click(sender: System.Object; e: System.EventArgs);
begin
try
// Create stream which holds the data
var dataStream := new AdsStream(MAX_ADSSTREAM_SIZE);
// Create BinaryWriter
var binWrite := new BinaryWriter(dataStream);
// Reset stream to start position
dataStream.Position := 0;
// Write structure member data to the stream
binWrite.Write(System.Int16.Parse(tbInt.Text));
binWrite.Write(System.Int32.Parse(tbDint.Text));
binWrite.Write(System.SByte.Parse(tbSInt.Text));
binWrite.Write(System.Double.Parse(tbLReal.Text));
binWrite.Write(System.Single.Parse(tbReal.Text));
// Write stream to the PLC
tcClient.Write(hVar,dataStream)
except
on err: Exception do
MessageBox.Show(err.Message, err.Source)
end;
end;
method MainForm.MainForm_FormClosing(sender: System.Object; e: System.Windows.Forms.FormClosingEventArgs);
begin
try
// Release PLC variable handle
tcClient.DeleteVariableHandle(hVar)
except
on err: Exception do
MessageBox.Show(err.Message, err.Source)
end;
// Close connection
tcClient.Dispose();
end;
method MainForm.MainForm_Load(sender: System.Object; e: System.EventArgs);
begin
try
// Create instance of class TcAdsClient
tcClient := new TcAdsClient();
// Create connection with Port 801 on local PC
tcClient.Connect(801);
// Create PLC variable handle
hVar := tcClient.CreateVariableHandle('MAIN.PLCVar')
except
on err: Exception do
MessageBox.Show(err.Message, err.Source)
end;
end;
end.
PLC program
TYPE PLCStruct :
STRUCT
intVal : INT;
dintVal : DINT;
sintVal : SINT;
lrealVal : LREAL;
realVal : REAL;
END_STRUCT
END_TYPE
PROGRAM MAIN
VAR
PLCVar:PLCStruct;
END_VAR
Requirements
Language / IDE | Unpack the sample program |
|---|---|
Delphi Prism (Embarcadero Prism XE2, Oxygene for .NET) | |
Delphi for .NET (Borland Developer Studio 2006) |