Transmitting structures to the PLC

This sample shows the transfer of a structure to the PLC via ADS. The structure consists of elements of different data types.

Download: sample20-c-ads-dll-writestructure.zip

#include <stdio.h>
#include <tchar.h>
#include "windows.h"

#include "c:\twincat\adsapi\tcadsdll\include\tcadsdef.h"
#include "c:\twincat\adsapi\tcadsdll\include\tcadsapi.h"

// Create new struct
typedef struct PlcStruct {
    INT16   shortVal;
    INT32   intVal;
    byte    byteVal;
    DOUBLE  doubleVal;
    FLOAT   floatVal; 
} SPlcVar, *pSPlcVar;

int _tmain(int argc, _TCHAR* argv[])
{
    long     nErr, nPort;
    AmsAddr  Addr;
    PAmsAddr pAddr = &Addr;
    ULONG     lHdlVar; 

    // New struct. Assign test values
    PlcStruct PlcVar;

    PlcVar.shortVal = 1;
    PlcVar.intVal = 2;
    PlcVar.byteVal = 3;
    PlcVar.doubleVal = 4.04;
    PlcVar.floatVal = (FLOAT)5.05;

    // Declare PLC variable which should notify changes
    char      szVar []={"MAIN.PLCVar"}; 


    // Extract values from struct and write to byte array
    // Circumvent memory holes caused by padding
    BYTE *pData = new BYTE[19];
    int nIOffs = 0;

    memcpy_s(&pData[nIOffs], 19, &PlcVar.shortVal, 2);
    nIOffs += 2;
    memcpy_s(&pData[nIOffs], 17, &PlcVar.intVal, 4);
    nIOffs += 4;
    memcpy_s(&pData[nIOffs], 13, &PlcVar.byteVal, 1);
    nIOffs++;
    memcpy_s(&pData[nIOffs], 12, &PlcVar.doubleVal, 8);
    nIOffs += 8;
    memcpy_s(&pData[nIOffs], 4, &PlcVar.floatVal, 4);


    // Open communication port on the ADS router
    nPort = AdsPortOpen();
    nErr = AdsGetLocalAddress(pAddr);
    if (nErr) printf("Error: Ads: Open port: %d\n", nErr);
    pAddr->port = 801;

    // Get variable handle
    nErr = AdsSyncReadWriteReq(pAddr,
                ADSIGRP_SYM_HNDBYNAME,
                0x0, 
                sizeof(lHdlVar), 
                &lHdlVar, 
                sizeof(szVar), 
                szVar);
    
    // Write the struct to the Plc
    AdsSyncWriteReq(    pAddr, 
            ADSIGRP_SYM_VALBYHND,   // IndexGroup 
            lHdlVar,            // IndexOffset
            0x13,           // Size of struct
            (void*) pData);
    
    if (nErr) printf("Error: Ads: Write struct: %d\n", nErr);
    else  printf("Structure successful written\n");
    
    // Close communication
    delete [] pData;
    
    //Release handle of plc variable
    nErr = AdsSyncWriteReq(pAddr, ADSIGRP_SYM_RELEASEHND, 0, sizeof(lHdlVar), &lHdlVar); 
    if (nErr) printf("Error: AdsSyncWriteReq: %d \n", nErr);

    nErr = AdsPortClose();
    if (nErr) printf("Error: Ads: Close port: %d\n", nErr);

    getchar();
}