AdsSyncReadWriteReq

AdsSyncReadWriteReq 1:

Delphi 5 program

unit frmAdsSyncReadWriteReqUnit;

interface

uses
  Windows, Messages, SysUtils, Classes, Graphics, Controls, Forms, Dialogs,
  StdCtrls, TcAdsDef, TcAdsApi, Buttons, ExtCtrls ;

type
  TfrmAdsSyncReadWriteReq = class(TForm)
    editValue: TEdit;
    Label1: TLabel;
    ComboBox1: TComboBox;
    Label4: TLabel;
    BitBtn1: TBitBtn;
    Button1: TButton;
    Bevel1: TBevel;
    editName: TEdit;
    Label2: TLabel;
    Label3: TLabel;
    Memo1: TMemo;
    Button2: TButton;
    procedure Button1Click(Sender: TObject);
    procedure Button2Click(Sender: TObject);
  private
    { Private-Deklarationen }
    serverAddr      : TAmsAddr;
  public
    { Public-Deklarationen }
    procedure InitData( destAddr : TAmsAddr );
  end;

type TPlcDataTypes =
(
    plcBOOL,
    plcBYTE,  //and USINT
    plcWORD,  //and UINT
    plcDWORD, //and UDINT
    plcSINT,
    plcINT,
    plcDINT,
    plcREAL,
    plcLREAL,
    plcSTRING
);


implementation

{$R *.DFM}
//////////////////////////////////////////////////////////////
procedure TfrmAdsSyncReadWriteReq.InitData( destAddr : TAmsAddr);
begin
     serverAddr := destAddr;
     ComboBox1.itemindex := 0;
end;
//////////////////////////////////////////////////////////////
procedure TfrmAdsSyncReadWriteReq.Button1Click( Sender: TObject);
var result          : longword;
    dataType        : TPlcDataTypes;
    hVar            : Longword;

    nBYTE           : Byte; //and USINT
    nWORD           : Word; //and UINT
    nDWORD          : Longword; //and UDINT
    iSINT           : Shortint;
    iINT            : Smallint;
    iDINT           : Longint;
    fREAL           : Single;
    fLREAL          : Double;
    sSTRING         : AnsiString;
    sName           : AnsiString;
begin
     Memo1.Lines.clear;
     dataType :=  TPlcDataTypes(ComboBox1.ItemIndex);

     sName := AnsiString(editName.Text);
     result := AdsSyncReadWriteReq(@serverAddr, ADSIGRP_SYM_HNDBYNAME, $0000, sizeof(hVar), @hVar, Length(sName)+1, @sName[1] );
     Memo1.Lines.add( Format( 'AdsSyncReadWriteReq(ADSIGRP_SYM_HNDBYNAME..) result: %d [0x%x], Handle: %d [0x%x]', [result, result, hVar, hVar]));

     if result = ADSERR_NOERR then
     begin

       case dataType of
       plcBOOL:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nBYTE), @nBYTE );
          editValue.Text := IntToStr(nByte And $01);
         end;
       plcBYTE:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nBYTE), @nBYTE );
          editValue.Text := IntToStr(nByte);
         end;
       plcWORD:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nWORD), @nWORD );
          editValue.Text := IntToStr(nWORD);
         end;
       plcDWORD:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nDWORD), @nDWORD );
          editValue.Text := IntToStr(nDWORD);
         end;
       plcSINT:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iSINT), @iSINT  );
          editValue.Text := IntToStr(iSINT);
         end;
       plcINT:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iINT), @iINT  );
          editValue.Text := IntToStr(iINT);
         end;
       plcDINT:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iDINT), @iDINT );
          editValue.Text := IntToStr(iDINT);
         end;
       plcREAL:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(fREAL), @fREAL );
          editValue.Text := FloatToStr(fREAL);
         end;
       plcLREAL:
         begin
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(fLREAL), @fLREAL );
          editValue.Text := FloatToStr(fLREAL);
         end;
       plcSTRING:
         begin
          SetLength(sSTRING, 256);//make sure the delphi string size is >= SIZEOF(plc string)
          result := AdsSyncReadReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, Length(sSTRING), @sSTRING[1] );
          editValue.Text := String(sSTRING);
         end;
       end;

       Memo1.Lines.add( Format( 'AdsSyncReadReq(ADSIGRP_SYM_VALBYHND..) result: %d [0x%x]', [result, result]));

       result := AdsSyncWriteReq( @serverAddr, ADSIGRP_RELEASE_SYMHND, $0000, sizeof( hVar), @hVar );

       Memo1.Lines.add( Format( 'AdsSyncWriteReq(ADSIGRP_RELEASE_SYMHND..) result: %d [0x%x]', [result, result]));

     end;
end;
//////////////////////////////////////////////////////////////
procedure TfrmAdsSyncReadWriteReq.Button2Click(Sender: TObject);
var result          : longword;
    dataType        : TPlcDataTypes;
    hVar        : Longword;

    nBYTE           : Byte; //and USINT
    nWORD           : Word; //and UINT
    nDWORD          : Longword; //and UDINT
    iSINT           : Shortint;
    iINT        : Smallint;
    iDINT           : Longint;
    fREAL           : Single;
    fLREAL          : Double;
    sSTRING         : AnsiString;
    sName           : AnsiString;
begin
     Memo1.Lines.clear;
     dataType :=  TPlcDataTypes(ComboBox1.ItemIndex);

     sName := AnsiString(editName.Text);
     result := AdsSyncReadWriteReq(@serverAddr, ADSIGRP_SYM_HNDBYNAME, $0000, sizeof(hVar), @hVar, Length(sName)+1, @sName[1] );
     Memo1.Lines.add( Format( 'AdsSyncReadWriteReq(ADSIGRP_SYM_HNDBYNAME..) result: %d [0x%x], Handle: %d [0x%x]', [result, result, hVar, hVar]));

     if result = ADSERR_NOERR then
     begin

       case dataType of
       plcBOOL:
         begin
          nByte := Byte(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nBYTE), @nBYTE );
         end;
       plcBYTE:
         begin
          nByte := Byte(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nBYTE), @nBYTE );
         end;
       plcWORD:
         begin
          nWORD := Word(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nWORD), @nWORD );
         end;
       plcDWORD:
         begin
          nDWORD := Longword(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(nDWORD), @nDWORD );
         end;
       plcSINT:
         begin
          iSINT := Shortint(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iSINT), @iSINT  );
         end;
       plcINT:
         begin
          iINT := Smallint(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iINT), @iINT  );
         end;
       plcDINT:
         begin
          iDINT := Longint(StrToInt(editValue.Text));
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(iDINT), @iDINT );
         end;
       plcREAL:
         begin
          fREAL := StrToFloat(editValue.Text);
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(fREAL), @fREAL );
         end;
       plcLREAL:
         begin
          fLREAL := StrToFloat(editValue.Text);
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, sizeof(fLREAL), @fLREAL );
         end;
       plcSTRING:
         begin
          sSTRING := AnsiString(editValue.Text);
          if sSTRING = '' then
            sSTRING := ''#00;
          result := AdsSyncWriteReq(@serverAddr, ADSIGRP_SYM_VALBYHND, hVar, Length(sSTRING)+1, @sSTRING[1] );
         end;
       end;

       Memo1.Lines.add( Format( 'AdsSyncWriteReq(ADSIGRP_SYM_VALBYHND..) result: %d [0x%x]', [result, result]));

       result := AdsSyncWriteReq( @serverAddr, ADSIGRP_RELEASE_SYMHND, $0000, sizeof( hVar), @hVar );

       Memo1.Lines.add( Format( 'AdsSyncWriteReq(ADSIGRP_RELEASE_SYMHND..) result: %d [0x%x]', [result, result]));

     end;
end;

end.