NC-PLC Errors

Error(Hex)

Error(dec)

Error type

Description

4B00

19200

Parameter

Axis was stopped.

The axis was stopped during travel to the target position. The axis may have been stopped with a PLC command via ADS, a call via AXFNC, or by the TwinCAT development environment.

4B01

19201

Parameter

The axis cannot be started.

The axis cannot be started because:

  • the axis is in error state,
  • the axis is executing another command,
  • the axis is in protected mode,
  • the axis is not ready for operation.

4B02

19202

Parameter

Control mode not permitted

No target position control, and no position area control.

4B03

19203

Parameter

Axis is not moving.

The position and velocity can only be restarted while the axis is physically in motion.

4B04

19204

Parameter

Mode invalid

Examples:
Invalid Direction with MC_MoveModulo.
Inactive axis parameter Position correction with MC_BacklashCompensation.

4B05

19205

Parameter

Command not permitted

  • Continuous motion in an unspecified direction
  • Read/Write parameter: unsuitable type

4B06

19206

Parameter

Parameter is not correct

  • Incorrect override: > 100 % or < 0 %
  • Incorrect gear ratio: RatioDenominator = 0

4B07

19207

Parameter

Timeout axis function block

After positioning all "MC_Move..."function blocks, check whether positioning was completed successfully. In the simplest case, the "AxisHasJob" flag of the NC axis is checked, which initially signifies that positioning was logically completed. Depending on the parameterization of the NC axis, further checks (quality criteria) are used:

  • "Position range monitoring":
    If position range monitoring is active, the system waits for feedback from the NC. After positioning, the axis must be within the specified positioning range window. If necessary, the position controller ensures that the axis is moved to the target position. If the position controller is switched off (Kv=0) or weak, the target may not be reached.
  • "Target position monitoring":
    If target position monitoring is active, the system waits for feedback from the NC. After positioning, the axis must be within the specified target position window for at least the specified time. If necessary, the position controller ensures that the axis is moved to the target position. If the position controller is switched off (Kv=0) or weak, the target may not be reached. Floating position control may lead to the axis oscillating around the window but not remaining inside the window.

If the axis is logically at the target position (logical standstill) but the parameterized position window has not been reached, monitoring of the above-mentioned NC feedback is aborted with error 19207 (0x4B07) after a constant timeout of 6 seconds.

4B08

19208

Parameter

Axis is in protected mode.

The axis is in protected mode (e.g. coupled) and cannot be moved.

4B09

19209

Parameter

Axis is not ready.

The axis is not ready and cannot be moved.

4B0A

19210

Parameter

Error during referencing

Referencing (homing) of the axis could not be started or was not successful.

4B0B

19211

Parameter

Incorrect definition of the trigger input

The definition of the trigger signal for function block MC_TouchProbe is incorrect. The defined encoder-ID, the trigger signal or the trigger edge are invalid.

4B0C

19212

Function

Position latch was disabled.

The function block MC_TouchProbe has detected that a touch probe cycle it had started was disabled. The reason may be an axis reset, for example.

4B0D

19213

Function

NC state feedback timeout

A function was successfully sent from the PLC to the NC. An expected feedback in the axis status word has not arrived.

4B0E

19214

Function

Additional product not installed.

The function is available as a supplement but is not installed on the system.

4B0F

19215

Function

No NC Cycle Counter Update

The NcToPlc Interface or the NC Cycle Counter in the NcToPlc Interface was not updated.

Error numbers 0x4B10 .. 0x4B2F are used in TwinCAT NCI context:

4B10

19216

Function

M-function query missing.

This error occurs if the M-function was confirmed, but the request bit was not set.

4B11

19217

Parameter

Zero shift index is outside the range.

The index of the zero offset shift is invalid.

4B12

19218

Parameter

R parameter index or size is invalid.

This error occurs if the R parameters are written or read but the index or size are outside the range.

4B13

19219

Parameter

Index for tool description is invalid.

The index for the tool description is invalid.

4B14

19220

Function

Version of the cyclic channel interface does not match the requested function or the function block.

This error occurs if an older TwinCAT version is used to call new functions of a later TcNci.lib version.

4B15

19221

Function

Channel is not ready for the requested function.

The requested function cannot be executed, because the channel is in the wrong state. This error occurs during reverse travel, for example, if the axis was not stopped with ItpEStop first.

4B16

19222

Function

Requested function is not activated.

The requested function requires explicit activation.

4B17

19223

Function

Axis is already in another group

The axis has already been added to another group.

4B18

19224

Function

Block search could not be executed successfully.

The block search has failed.

Possible causes:

  • Invalid block number

4B19

19225

Parameter

Blocksearch parameter invalid

This error occurs if the function block ItpBlocksearch is called with invalid parameters (e.g. E_ItpDryRunMode, E_ItpBlockSearchMode).

4B20

19232

Function

Cannot add all axes

This error occurs if an auxiliary axis is to be added to an interpolation group, but the function fails. It is likely that a preceding instruction of an auxiliary axis was skipped.

Error numbers 0x4B30 .. 0x4B3F are used in the TcMcCam-Library (MC_NC_TableErrorCodes):

4B30

19248

Parameter

Pointer is invalid.

A pointer to a data structure is invalid, e.g. Null.

  • Data structure MC_CAM_REF was not initialized.

4B31

19249

Parameter

Memory size invalid

The specification of the memory size (SIZE) for a data structure is invalid.

  • Memory size is 0 or smaller than an element of the addressed data structure.
  • Memory size is smaller than the requested amount of data.
  • Memory size does not match other parameters, such as number of points, number of rows or number of columns.

4B32

19250

Parameter

Cam plate ID is invalid.

The ID of a cam plate is not between 1 and 255.

4B33

19251

Parameter

Point ID is invalid.

The ID of a point (interpolation point) of a motion function is less than 1.

4B34

19252

Parameter

Number of points is invalid.

The number of points (interpolation points) of a cam plate to be read or written is less than 1.

4B35

19253

Parameter

MC table type is invalid.

The type of a cam plate does not match the definition MC_TableType.

4B36

19254

Parameter

Number of rows invalid

The number of rows (interpolation points) of a cam plate is less than 1.

4B37

19255

Parameter

Number of columns invalid

The number of columns of a cam plate is invalid.

  • The number of columns of a motion function is not equal 1.
  • The number of columns of a standard cam plate is not equal 2.
  • The number of columns does not match another parameter (ValueSelectMask).

4B38

19256

Parameter

Step size invalid

The step size for the interpolation is invalid, e.g. less than or equal to zero.

Error numbers 0x4B0F, 0x4B40 .. 0x4B4F are used in several libraries (TcNc-Library / Tc2_MC2_XFC-Library):

4B40

19264

Monitoring

Terminal type not supported

The terminal used is not supported by this function block.

4B41

19265

Monitoring

Register read/write error

This error implies a validity error.

4B42

19266

Monitoring

Axis is enabled.

The axis is enabled but should not be enabled for this process.

4B43

19267

Parameter

Incorrect size of the compensation table

The specified table size (in bytes) does not match the actual size.

4B44

19268

Parameter

Positional deviation

The minimum/maximum position in the compensation table does not match the position in the table description (ST_CompensationDesc).

4B45

19269

Parameter

Not implemented

The requested function is not implemented in this combination.

4B46

19270

Parameter

Window not in the specified modulo range

The parameterized min or max position is not in the specified modulo range.

4B47

19271

Monitoring

Buffer overflow

The number of events has led to an overflow of the buffer and not all events could be acquired.

Error numbers 0x4B50 .. 0x4B5F are used in the TcMcCam-Library :

Error numbers 0x4B60 .. 0x4B6F are used in the TcMc2-Library in the buffered commands context:

4B60

19296

Monitoring

Motion command did not become active.

A motion command has been started and has been buffered and confirmed by the NC. Nevertheless, the motion command did not become active (possibly due to a termination condition or an internal NC error).

4B61

19297

Monitoring

Motion command could not be monitored by the PLC.

A motion command has been started and has been buffered and confirmed by the NC. The PLC has not been able to monitor the execution of this command and the execution status is unclear since the NC is already executing a more recent command. The execution state is unclear. This error may come up with very short buffered motion commands which are executed during one PLC cycle.

4B62

19298

Monitoring

Buffered command was terminated with an error.

A buffered command was terminated with an error. The error number is not available, because a new command is already being executed.

4B63

19299

Monitoring

Buffered command was completed without feedback

A buffered command was completed but there was no feedback to indicate success or failure.

4B64

19300

Monitoring

'BufferMode' is not supported by the command.

The 'BufferMode' is not supported by this command.

4B65

19301

Monitoring

Command number is zero.

The command number for queued commands managed by the system unexpectedly has the value 0.

4B66

19302

Monitoring

Function block was not called cyclically.

The function block was not called cyclically. The command execution could not be monitored by the PLC, because the NC was already executing a subsequent command. The execution state is unclear.

Error numbers 0x4B70 .. 0x4B8F are used in the TcPlcInterpolation-Library :

4B71

19313

Parameter

NCI Entry type invalid

The FB FB_NciFeedTablePreparation was called with an unknown nEntryType.

4B72

19314

Function

NCI feed table full

The table is full and therefore the entry is not accepted.
Remedy:
Transfer the contents to the NC kernel with the function block FB_NciFeedTable. If bFeedingDone = TRUE, the table can be reset in FB_NciFeedTablePreparation with bResetTable and then filled with new entries.

4B73

19315

Function

Internal error

 

4B74

19316

Parameter

ST_NciTangentialFollowingDesc: Tangential axis is not an auxiliary axis.

The entry for tangential following contains a tangential axis that is not an auxiliary axis.

4B75

19317

Parameter

ST_NciTangentialFollowingDesc

nPathAxis1 or nPathAxis2 is not a path axis. It is therefore not possible to determine the plane.

4B76

19318

Parameter

ST_NciTangentialFollwoingDesc

nPathAxis1 and nPathAxis2 are the same. It is therefore not possible to determine the plane.

4B77

19319

Parameter

ST_NciGeoCirclePlane

Circle incorrectly parameterized

4B78

19320

Function

Internal error

An internal error has occurred in the calculation of the tangential following.

4B79

19321

Monitoring

Tangential following

Monitoring of the deviation angle was activated during activation of tangential following (E_TfErrorOnCritical1), and an excessively large deviation angle was detected in the current segment.

4B7A

19322

Function

Reserved

Reserved, currently not used.

4B7B

19323

Parameter

Tangential following

The radius of the current arc is too small.

4B7C

19324

Parameter

FB_NciFeedTablePreparation

pEntry is NULL

4B7D

19325

Parameter

FB_NciFeedTablePreparation

The specified nEntryType does not match the structure type.

4B7E

19326

Parameter

ST_NciMFuncFast and ST_NciMFuncHsk

The requested M-function is not between 0 and 159.

4B7F

19327

Parameter

ST_NciDynOvr

The requested value for the dynamic override is not between 0.01 and 1

4B80

19328

Parameter

ST_NciVertexSmoothing

Invalid parameter. This error is generated if a negative smoothing radius or an unknown smoothing type is encountered.

4B81

19329

Parameter

FB_NciFeedTablePrepartion

The requested velocity is not in the valid range.

4B82

19330

Parameter

ST_Nci*

Invalid parameter

Error numbers 0x4B90 .. 0x4B9F are used in the Tc3_MC2_AdvancedHoming-Library (PLCopen Part 5: Homing Procedures):

4B90

19344

Parameter

Drive type

The determined drive type is not supported.

4B91

19345

Parameter

Direction

The direction is impermissible.

4B92

19346

 

SwitchMode

The SwitchMode is impermissible.

4B93

19347

 

Mode

The mode for the parameter handling is impermissible.

4B94

19348

 

Torque limits

The parameterization of the torque limits is inconsistent.

4B95

19349

 

Lag error limit

The parameterization of the position lag limit is impermissible (<=0).

4B96

19350

 

Distance limit

The parameterization of the distance limit is impermissible (<0).

4B97

19351

 

Saving parameters

An attempt was made to back up parameters again, although they have already been backed up.

4B98

19352

 

Restoring parameters

An attempt was made to restore parameters, although none have been backed up.

4B9F

19359

 

Cancellation of a homing

The abortion of a homing has failed.

Error numbers 0x4BA0 .. 0x4BAF are used in the TcNcKinematicTransformation-Library :

4BA0

19360

Function

KinGroup error

The kinematic group is in an error state.

This error may occur if the kinematic group is in an error state or an unexpected state when it is called (e.g., simultaneous call via several function block instances).

4BA1

19361

Function

KinGroup timeout

Timeout during call of a kinematic block

Error numbers 0x4BB0 .. 0x4BBF are used in the Tc2_MC2_Drive-Library :

4BB0

19376

Function

Invalid axis position

The current axis position or the axis position resulting from the new position offset exceeds the valid range of values.

4BB1

19377

Function

Position offset invalid

The new position offset exceeds the valid range of values [AX5000: 2^31].

4BB2

19378

Function

Invalid axis position

The current axis position or the axis position resulting from the new position offset falls below the valid range of values.

4BB3

19379

Function

Position offset invalid

The new position offset falls below the valid range of values [AX5000: -2^31].

4BB4

19380

Function

Deviation of the activated feedback and/or storage location

The activated feedback and/or storage location (AX5000: P-0-0275) differ from the parameterization on the function block.

4BB5

19381

Function

Reinitialization of the NC actual position has failed.

The reinitialization of the actual NC position has failed, e.g., reference system = "ABSOLUTE (with single overflow)" & software end position monitoring is disabled.

4BB6

19382

Function

The setting or deletion of a position offset was rejected.

The command to set or delete a position offset was rejected without feedback data, e.g., if the drive controller's firmware does not support the corresponding command.

4BB7

19383

Function

The setting or deletion of a position offset was rejected.

The command to set or delete a position offset was rejected with feedback data. The information in the feedback data may contain further clues to the cause, e.g. if the firmware of the drive controller does not support the corresponding command.

4BB8

19384

Function

Firmware version invalid

A firmware version >= 19 is required for the servo terminal.

4BB9

19385

Function

Different modulo settings

The modulo settings on the drive controller and in the NC are different.

4BBA

19386

Function

Brake test failed

The brake test has failed.

4BBB

19387

Function

Drive type not supported

The determined drive or axis type is not supported.

4BBC

19388

Function

Command was aborted.

The command was aborted by another command.

4BBD

19389

Function

Timeout

The command was aborted due to timeout.

4BBE

19390

Function

Incorrect Data Type

An incorrect data type was used when reading or writing a drive parameter (FB_ReadDriveParameter / FB_WriteDriveParameter).

4BBF

19391

Function

Drive parameter not supported

An attempt is being made to read or write a drive parameter that is not supported by the drive hardware.

Error numbers 0x4BC0 .. 0x4BCF are used in the Tc3_DriveMotionControl-Library

4BC2

19394

 

Position offset invalid

The new position offset exceeds the valid value range.

4BC3

19395

 

I/O data invalid

I/O data are invalid or the terminal is in an error state.

4BC4

19396

 

ADS port not linked in the interface

The ADS port variable of the terminal was not linked to the axis interface of the PLC and parameters of the terminal are to be changed.