General NC Errors
Error(Hex) | Error(Dec) | Error type | Description |
|---|---|---|---|
4000 | 16384 | Internal | Internal error Internal system error in the NC on ring 0, no further details. |
4001 | 16385 | Memory | Memory error The ring-0 memory management is not providing the required memory. This is usually a result of another error, as a result of which the controller will halt normal operation (now if not before). |
4002 | 16386 | Internal | NC Retain data error (persistent data) An error occurred when loading the NC Retain data, so that the affected axes are no longer referenced (status bit "Homed" is FALSE). |
4003 | 16387 | Parameter | Parameter for monitoring the NC setpoint output is invalid The parameter for activating or deactivating the "cyclic monitoring of NC setpoint output for steadiness and consistency" function is invalid. (Special function) |
4004 | 16388 | Internal | External error This error code can be set by an external module (e.g. third-party module) or can be set if an external module has an error. |
4010 | 16400 | Parameter | Channel identifier not allowed Either an unacceptable value (not 1...255) has been used, or a channel that does not exist in the system has been named. |
4011 | 16401 | Parameter | Group identifier not allowed Either an unacceptable value (not 1...255) has been used, or a group that does not exist in the system has been named. |
4012 | 16402 | Parameter | Axis identifier not allowed Either an unacceptable value (not 1...255) has been used, or an axis that does not exist in the system has been named. |
4013 | 16403 | Parameter | Encoder identifier not allowed Either an unacceptable value (not 1...255) has been used, or a encoder that does not exist in the system has been named. |
4014 | 16404 | Parameter | Controller identifier not allowed Either an unacceptable value (not 1...255) has been used, or a controller that does not exist in the system has been named. |
4015 | 16405 | Parameter | Drive identifier not allowed Either an unacceptable value (not 1...255) has been used, or a drive that does not exist in the system has been named. |
4016 | 16406 | Parameter | Table identifier not allowed Either an unacceptable value (not 1...255) has been used, or a table that does not exist in the system has been named. |
4020 | 16416 | Internal | Missing process image There is no PLC-axis interface when creating an axis. |
4021 | 16417 | Internal | Missing process image There is no axis-PLC interface when creating an axis. |
4022 | 16418 | Internal | Missing process image There is no encoder-I/O interface when creating an axis. |
4023 | 16419 | Internal | Missing process image There is no I/O-encoder interface when creating an axis. |
4024 | 16420 | Internal | Missing process image There is no drive-I/O interface when creating an axis. |
4025 | 16421 | Internal | Missing process image There is no I/O-drive interface when creating an axis. |
4030 | 16432 | Internal | Coupling type not allowed The master/slave coupling type is not allowed. |
4031 | 16433 | Internal | Axis type not allowed The type specification in the axis generation is inadmissible. |
4032 | 16434 | Parameter | Unknown channel type The NC channel type is unknown. Known types are e.g. an NCI channel, a FIFO channel, etc. |
4040 | 16448 | Internal | Axis is incompatible The axis is not suitable for the intended purpose. A high speed/low speed axis, for example, cannot function as a slave in an axis coupling. |
4050 | 16464 | Internal | Channel not ready to operate The channel is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. |
4051 | 16465 | Internal | Group not ready to operate The group is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. |
4052 | 16466 | Internal | Axis not ready to operate The axis is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. |
4060 | 16480 | Internal | Channel exists The channel that is to be created already exists. |
4061 | 16481 | Internal | Group exists The group that is to be created already exists. |
4062 | 16482 | Internal | Axis exists The axis that is to be created already exists. |
4063 | 16483 | Internal | Table exists The table that is to be created already exists, or attempts are made to use an already existing table id internally ( e.g. for the universal flying saw). |
4070 | 16496 | Internal | Axis index not allowed The location within the channel specified for an axis is not allowed. |
4071 | 16497 | Internal | Axis index not allowed The location within the group specified for an axis is not allowed. |