Command Force FB input

Command Force FB input 1:

Available from TwinCAT 3.1 Build 4026

Command Force FB input 2:

This type of forcing uses a breakpoint internally and is therefore to be distinguished from forcing via the command Force values: Values that have been forced via the command Force FB input do not respond to the commands Watch all forces or Cancel forcing for all values.

Function: The command opens a dialog Force value for forcing the selected input of a function block. Forcing can be canceled with the same command and dialog.

Call: CFC menu, context menu

Requirements: The CFC editor is in online mode and the input of the function block is selected.

In the dialog Force value you can either enter a value with which the input of the function block is to be forced, or remove the currently forced value again.

After forcing, the input appears with a green background. Boolean inputs also get a small monitoring window with the forced value. The forced value is displayed in the column Value of monitoring views, i.e. in the declaration part of the program block or in a watch list.

Force value dialog

Expression

Name of the function block input

Type

Input data type

What do you want to do?

Set a new value to force

You can enter the desired new value in the input field. The format must correspond to the data type.

Remove value

Forcing at the input is canceled.