Determining the file fingerprint of the OEM certificate file
You need this functionality to request a TwinCAT OEM Certificate Extended Validation (TC0008).
|  | System requirements This functionality requires TwinCAT 3.1 Build 4024 of higher. | 
|  | The OEM Certificate Request File becomes the TwinCAT OEM certificate once it is signed by Beckhoff. The files do not differ except for this signature. For this reason, the term "TwinCAT OEM certificate file" is used for both file versions in the following sections. | 
Reading the "file fingerprint" of an OEM certificate file via TwinCAT 3 Engineering
For this function it is necessary that the OEM certificate file is located in this directory: "c:\twincat\3.1\customconfig\certificates".
This directory contains your OEM certificate, if you already have a certificate and want to renew it.
If you did not change the suggested directory when creating the "OEM Certificate Request File", the file is already in this directory.
Procedure:
- Call up the TwinCAT 3 Software Protection configurator. 
- Select the Certificates tab.
- Check the Extended Info checkbox.
- In the window scroll to the right until you see the Fingerprint column. (As an alternative, you can simply double-click the certificate line. The Fingerprint file is then displayed in a pop-up window: 
|  | The shortcut [Ctrl] + [C] can be used to copy the fingerprint data from the message window to the Windows clipboard. |