Command Call Stack
Symbol: 
Function: The command opens the Call Stack view.
Call: Menu PLC > Window
Callstack view
This view is useful if you want to run programs step-by-step. It shows the currently reached position with the complete call path.

Application | Name of the active PLC project that controls the currently reached program block. |
Task | Name of the task that controls the currently reached program block. |
POU | Name of the program block in which the program execution is located. The first line in the list describes the current execution position. It is marked with a yellow arrow. If this position is in a function block called by another function block, the position of the call is described in the second line. If the caller is called by another function block, this call position is described in the third line and so on. |
Location | Position within the program block where the program execution is located
|
Instance path | Instance in which the program is executed. |
The Call Stack is also available in offline mode and in normal online mode if you are not using any debugging functions. In this case, it contains the last position displayed during a step-by-step execution, but in "gray" font.
![]() | In contrast to the Call Stack view, the Call Tree view provides call information on a function block at any time. |
See also:
- PLC documentation: Use of breakpoints