config
Command: config
Description: This command is used to query and change the configuration of TcPkg CLI.
Use: tcpkg config [subcommand] [options]
Subcommands:
Subcommand: list
Description: Use this command to query all configurations.
Use: tcpkg config list
Subcommand: set
Description: Use this command to set a configuration option.
Use: tcpkg config set -n [options]
Options:
useVS2017|useVS2019|useVS2022|useTcXaeShell|useTcXaeShell64
This option configures the integration into the TcXaeShell, TcXaeShell64 or a Visual Studio version. In an existing installation, if you change the Visual Studio integration, you must also install the corresponding packages using: tcpkg install <vs2017.ext|vs2019.ext|vs2022.ext|tcxaeshell.ext|tcxaeshell64.ext>
verifySignatures
This option configures Beckhoff package signatures to be checked. (Default: enabled)
tcPkgVersionOutput
This option configures the TcPkg version to be displayed at the beginning of the output when a command is executed. (Default: enabled)
logLevel -v <verbose|information>
This option configures the level at which TcPkg enters log entries in the corresponding file. (Default: information)
xarMode -v <UM|KM|KMWithUM>
This option configures the runtime mode. (Default: depends on the system; see Runtime Configuration)
Samples:
Setting the Visual Studio integration and subsequent installation of the integration:
tcpkg config set -n useVS2022
tcpkg install vs2022.ext
Changing the logging data:
tcpkg config set -n logLevel -v verbose
Changing the runtime mode:
tcpkg config set -n xarMode -v KM
Subcommand: unset
Description: Use this command to reset a configuration option.
Use: tcpkg config unset -n [options]
Options:
useVS2017|useVS2019|useVS2022|useTcXaeShell|useTcXaeShell64
This option removes the configuration for TwinCAT integration in the TcXaeShell, TcXaeShell64 or a Visual Studio version. To remove all integration packages, execute the following command: tcpkg uninstall <vs2017.ext|vs2019.ext|vs2022.ext|tcxaeshell.ext|tcxaeshell64.ext>
verifySignatures
This option configures the package signatures to not be checked.
tcPkgVersionOutput
This option removes the output of the TcPkg version when executing a command.
logLevel <verbose|information>
This option configures the "information" level with which TcPkg enters log entries in the corresponding file.
xarMode <UM|KM|KMWithUM>
This option configures the default runtime mode.
Sample:
tcpkg config unset -n <useVS2017|useVS2019|useVS2022|useTcXaeShell|useTcXaeShell64|verifySignatures|logLevel|tcPkgVersionOutput|xarMode>
Subcommand: set proxy
Description: Use this command to configure the information of a proxy.
Use: tcpkg config set proxy [options]
Options:
-d, --domain <domain>
Specification of the domain of the proxy in the form <protocol header><IP adress>:<port>
-u, --user <user>
Username for logging in to the proxy, you will then be asked for the password.
--bypass-on-local
Option to bypass the proxy for local connections.
Sample:
tcpkg config set proxy -d https://127.0.0.1:80 -u example.user@mail.com