Valves

The following table lists valve controls and their descriptions.

Control

Icon

Description

Angle Ball Type Valve

Valves 1:

Valve, angle ball type (ISO X8072).

Angle Globe Type Safety Valve

Valves 2:

Safety valve, spring loaded, globe angle type (ISO X2125).

Angle Globe Type Valve

Valves 3:

Valve, angle globe type (ISO X8069).

Angle Type Valve

Valves 4:

Valve, angle type (general) (ISO 2102).

Ball Type Valve

Valves 5:

Valve, ball type (ISO X8071).

Butterfly Type Form1 Valve

Valves 6:

Valve, butterfly type (Form 1) (ISO X8075).

Diaphragm Valve

Valves 7:

Diaphragm Valve

Control Type Valve

Valves 8:

Valve, control type, continuously operated (ISO X8087).

Four Way Valve

Valves 9:

Four way valve (general).

Gate Type Valve

Valves 10:

Valve, gate type (ISO X8074).

General Valve

Valves 11:

Valve (general) (ISO 2101).

Globe Type Safety Valve

Valves 12:

Safety valve, spring loaded, globe type (ISO X2124).

Globe Type Valve

Valves 13:

Valve, globe type (ISO X8068).

Needle Type Valve

Valves 14:

Valve, needle type (ISO X8076).

Three Way Ball Type Valve

Valves 15:

Valve, three way ball type (ISO X8073).

Three Way Globe Type Valve

Valves 16:

Valve, three way globe type (ISO X8070).

Three Way Type Valve

Valves 17:

Valve, three way type (general) (ISO 2103).

Element baseValve doesn’t add any other properties, functions, or events compared to ProcessObject. Elements baseThreeWayTypeValve and baseFourWayValve add the Valve Position property in the category Common. Thus, Three Way Type Valve and Four Way Valve controls inherit this behavior from their base element, but nevertheless, Graphic Status property has priority over the Valve Position one. Valve Position property is handled in different ways for three and four way valves.

The following table shows the correspondence between Valve Position property and appearance of three way valve control:

Valve Position

value

0

1

2

3

4

5

6

7

Any other

Appearance

Valves 18:

Valves 19:

Valves 20:

Valves 21:

Valves 22:

Valves 23:

Valves 24:

Valves 25:

Valves 26:

The following table shows the correspondence between Valve Position property and appearance of four way valve control:

Valve Position

value

0

1

2

3

4

5

6

7

Appearance

Valves 27:

Valves 28:

Valves 29:

Valves 30:

Valves 31:

Valves 32:

Valves 33:

Valves 34:

Valve Position

value

8

9

10

11

12

13

14

15

Appearance

Valves 35:

Valves 36:

Valves 37:

Valves 38:

Valves 39:

Valves 40:

Valves 41:

Valves 42:

Valve Position

value

16

17

18

19

20

21

Any other

 

Appearance

Valves 43:

Valves 44:

Valves 45:

Valves 46:

Valves 47:

Valves 48:

Valves 49: