ITcPlcProject

The class ITcPlcProject enables developers to set properties for a PLC project. It usually targets the root node of a PLC project, as shown in the picture below.

ITcPlcProject 1:

The following C# code snippet shows an example about how this class may be used in Automation Interface code:

 

Please note: If you would like tocompile a PLC project, please use the compiler functionalities of the Visual Studio COM objectEnvDTE, as shown in many of our Samples .

Methods

ITcPlcProject methods

Description

Available since

GenerateBootProject()

Equals the entry "Activate Boot project" from the TwinCAT XAE context menu

TwinCAT 3.1

Properties

ITcPlcProject properties

Get/Set

Description

Available since

BootProjectAutoStart

Yes / Yes

Equals the checkbox "Autostart Boot Project" in the dialog shown above

TwinCAT 3.1

BootProjectEncryption

Yes / Yes

Equals the dropdown box "Encryption" in the dialog shown above

TwinCAT 3.1

TmcFileCopy

Yes / Yes

Equals the checkbox "Copy TMC File to Target" in the dialog shown above

TwinCAT 3.1

Version information

Required TwinCAT version

This interface is supported in TwinCAT 3.1 and above