How to manage routes
Routes can be added using ConsumeXml on the route node. It is not possible to delete items directly via the Automation Interface. An alternative is to edit StaticRoutes.xml directly. The project's target Net ID can be easily set and retrieved via ITcSysManager2.
![]() | Only unencrypted routes are created using this method; ADS Secure / encrypted routes are not supported. |
Requirements
TwinCAT 3 is installed. To delete a route, you need write access to:
C:\TwinCAT\3.1\TargetStaticRoutes.xml
Adding a route using an IP address
C#:
string xmlString = "<TreeItem><RoutePrj><TargetList><BroadcastSearch>true</BroadcastSearch></TargetList><AddRoute><RemoteName>RouteName</RemoteName><RemoteNetId>10.1.128.217.1.1</RemoteNetId><RemoteIpAddr>10.1.128.217</RemoteIpAddr><UserName>Administrator</UserName><Password>1</Password><NoEncryption></NoEncryption></AddRoute></RoutePrj></TreeItem>";
ITcSmTreeItem routes = systemManager.LookupTreeItem("TIRR");
routes.ConsumeXml(xmlString);PowerShell:
$xmlString ="<TreeItem><ItemName>Route Settings</ItemName><PathName>TIRR</PathName><RoutePrj><TargetList><BroadcastSearch>true</BroadcastSearch></TargetList><AddRoute><RemoteName>RouteName</RemoteName><RemoteNetId>10.1.128.217.1.1</RemoteNetId><RemoteIpAddr>10.1.128.217</RemoteIpAddr><UserName>Administrator</UserName><Password>1</Password><NoEncryption></NoEncryption></AddRoute></RoutePrj></TreeItem>"
$routes = $systemManager.LookupTreeItem("TIRR")
$routes.ConsumeXml($xmlString)Adding a route using a hostname
<TreeItem>
<ItemName>Route Settings</ItemName>
<PathName>TIRR</PathName>
<RoutePrj>
<TargetList>
<BroadcastSearch>true</BroadcastSearch>
</TargetList>
<AddRoute>
<RemoteName>RouteName</RemoteName>
<RemoteNetId>1.2.3.4.5.6</RemoteNetId>
<RemoteHostName>CX-12345</RemoteHostName>
<UserName>userName</UserName>
<Password>password</Password>
<NoEncryption></NoEncryption>
<LocalName>LocalName</LocalName>
</AddRoute>
</RoutePrj>
</TreeItem>
Adding a project route
<TreeItem>
<ItemName>Route Settings</ItemName>
<PathName>TIRR</PathName>
<RoutePrj>
<TargetList>
<BroadcastSearch>true</BroadcastSearch>
</TargetList>
<AddProjectRoute>
<Name>RouteName</Name>
<NetId>1.2.3.4.5.6</NetId>
<IpAddr>1.2.3.4</IpAddr>
</AddProjectRoute>
</RoutePrj>
</TreeItem>
![]() | The XML structure for regular and project routes can be used simultaneously. |
Setting and reading Net ID
// Net-ID setzen (ITcSysManager2)
ITcSysManager2 sysMan2 = (ITcSysManager2)sysManager;
sysMan2.SetTargetNetId("5.23.233.156.1.1"); // Auf Remote-System
sysMan2.SetTargetNetId(""); // Zurück auf lokales System
string currentNetId = sysMan2.GetTargetNetId();
Deleting a route from StaticRoutes.xml
var xmlDoc = new System.Xml.XmlDocument();
xmlDoc.Load(@"C:\TwinCAT\3.1\Target\StaticRoutes.xml");
string routeToRemove =
"<Route>" +
"<Name>CX-17E99C</Name>" +
"<Address>CX-17E99C</Address>" +
"<NetId>5.23.233.156.1.1</NetId>" +
"<Type>TCP_IP</Type>" +
"</Route>";
string xmlString = xmlDoc.InnerXml;
xmlString = xmlString.Replace(routeToRemove, "");
xmlDoc.InnerXml = xmlString;
xmlDoc.Save(@"C:\TwinCAT\3.1\Target\StaticRoutes.xml");
![]() |
|