ReadOnlyDataTypeCollection.T. Class

ReadOnly DataType collection

Inheritance Hierarchy

System.Object
  System.Collections.ObjectModel.ReadOnlyCollection.T.
    TwinCAT.TypeSystem.Generic.ReadOnlyDataTypeCollection.T.
      TwinCAT.TypeSystem.ReadOnlyDataTypeCollection
Namespace:  TwinCAT.TypeSystem.Generic
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class ReadOnlyDataTypeCollection<T> : ReadOnlyCollection<T>, 
    IDataTypeContainer<T>
where T : IDataType

VB

Public Class ReadOnlyDataTypeCollection(Of T As IDataType)
    Inherits ReadOnlyCollection(Of T)
    Implements IDataTypeContainer(Of T)

Type Parameters

T

The ReadOnlyDataTypeCollection.T. type exposes the following members.

Constructors

 

Name

Description

ReadOnlyDataTypeCollection.T. Class 1:

ReadOnlyDataTypeCollection.T.(DataTypeCollection.T.)

Initializes a new instance of the ReadOnlyDataTypeCollection.T. class.

ReadOnlyDataTypeCollection.T. Class 2:

ReadOnlyDataTypeCollection.T.(ReadOnlyDataTypeCollection.T.)

Initializes a new instance of the ReadOnlyDataTypeCollection.T. class.

Properties

 

Name

Description

ReadOnlyDataTypeCollection.T. Class 3:

Count

Gets the number of elements contained in the ReadOnlyCollection.T. instance. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 4:

Item.Int32.

Gets the element at the specified index. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 5:

Item.String.

Gets the element with the specified type name.

ReadOnlyDataTypeCollection.T. Class 6:

Items

Returns the IList.T. that the ReadOnlyCollection.T. wraps. (Inherited from ReadOnlyCollection.T..)

Methods

 

Name

Description

ReadOnlyDataTypeCollection.T. Class 7:

Contains

Determines whether an element is in the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 8:

ContainsType

Determines whether the specified name contains type.

ReadOnlyDataTypeCollection.T. Class 9:

CopyTo

Copies the entire ReadOnlyCollection.T. to a compatible one-dimensional Array, starting at the specified index of the target array. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 10:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 11:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 12:

GetEnumerator

Returns an enumerator that iterates through the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 13:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 14:

GetType

Gets the Type of the current instance. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 15:

IndexOf

Searches for the specified object and returns the zero-based index of the first occurrence within the entire ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.T..)

ReadOnlyDataTypeCollection.T. Class 16:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 17:

ToString

Returns a string that represents the current object. (Inherited from Object.)

ReadOnlyDataTypeCollection.T. Class 18:

TryGetType

Tries to get the Type with the specified name out of the collection.

Reference

TwinCAT.TypeSystem.Generic Namespace