DynamicReferenceValue Class

Class DynamicReferenceValue.

Inheritance Hierarchy

System.Object
  System.Dynamic.DynamicObject
    TwinCAT.TypeSystem.DynamicValue
      TwinCAT.TypeSystem.DynamicReferenceValue
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class DynamicReferenceValue : DynamicValue

VB

Public Class DynamicReferenceValue
    Inherits DynamicValue

The DynamicReferenceValue type exposes the following members.

Properties

 

Name

Description

DynamicReferenceValue Class 1:

Age

Gets the age of the value (last successful read of the value) (Inherited from DynamicValue.)

DynamicReferenceValue Class 2:

CachedRaw

Gets the cached Raw internal Data. (Inherited from DynamicValue.)

DynamicReferenceValue Class 3:

DataType

Gets the data type bound to this IValue (Inherited from DynamicValue.)

DynamicReferenceValue Class 4:

IsPrimitive

Gets a value indicating whether this IValue is a primitive value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 5:

ResolvedType

Gets the resolved type. (Inherited from DynamicValue.)

DynamicReferenceValue Class 6:

Symbol

Gets the symbol that is bound to this value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 7:

UtcTimeStamp

Gets the Time stamp of the last successful read of the Value. (Inherited from DynamicValue.)

Methods

 

Name

Description

DynamicReferenceValue Class 8:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

DynamicReferenceValue Class 9:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

DynamicReferenceValue Class 10:

GetDynamicMemberNames

Returns the enumeration of all dynamic member names. (Inherited from DynamicValue.)

DynamicReferenceValue Class 11:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

DynamicReferenceValue Class 12:

GetMetaObject

Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.)

DynamicReferenceValue Class 13:

GetType

Gets the Type of the current instance. (Inherited from Object.)

DynamicReferenceValue Class 14:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

DynamicReferenceValue Class 15:

Read

Reads the value (via ADS) (Inherited from DynamicValue.)

DynamicReferenceValue Class 16:

ReadMember

Reads the specified member element. (Overrides DynamicValue.ReadMember(ISymbol).)

DynamicReferenceValue Class 17:

ResolveValue

Resolves the Value object to its primitive value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 18:

ToString

Returns a String that represents this instance. (Inherited from DynamicValue.)

DynamicReferenceValue Class 19:

TryBinaryOperation

Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.)

DynamicReferenceValue Class 20:

TryConvert

Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicValue.)

DynamicReferenceValue Class 21:

TryCreateInstance

Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceValue Class 22:

TryDeleteIndex

Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceValue Class 23:

TryDeleteMember

Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceValue Class 24:

TryGetArrayElementValues

Returns Array Element values. (Inherited from DynamicValue.)

DynamicReferenceValue Class 25:

TryGetIndex

Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Inherited from DynamicValue.)

DynamicReferenceValue Class 26:

TryGetIndexValue(.Int32., Object.)

Reads the specified array element. (Inherited from DynamicValue.)

DynamicReferenceValue Class 27:

TryGetIndexValue(.Object., Object.)

Tries the get index value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 28:

TryGetMember

Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Inherited from DynamicValue.)

DynamicReferenceValue Class 29:

TryGetMemberValue

Tries the get member value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 30:

TryInvoke

Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicValue.)

DynamicReferenceValue Class 31:

TryInvokeMember

Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Inherited from DynamicValue.)

DynamicReferenceValue Class 32:

TryResolveValue

Tries to resolves the Value object to its primitive value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 33:

TrySetIndex

Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Inherited from DynamicValue.)

DynamicReferenceValue Class 34:

TrySetIndexValue

Tries to set the indexed value on Arrays (Inherited from DynamicValue.)

DynamicReferenceValue Class 35:

TrySetMember

Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Inherited from DynamicValue.)

DynamicReferenceValue Class 36:

TrySetMemberValue

Tries to Set a Member/Property Value (Inherited from DynamicValue.)

DynamicReferenceValue Class 37:

TryUnaryOperation

Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.)

DynamicReferenceValue Class 38:

Write

Writes the value (via ADS) (Inherited from DynamicValue.)

DynamicReferenceValue Class 39:

WriteMember

Writes the specified member element. (Inherited from DynamicValue.)

Fields

 

Name

Description

DynamicReferenceValue Class 40:

_symbol

Symbol that is bound to this value. (Inherited from DynamicValue.)

DynamicReferenceValue Class 41:

valueFactory

The value factory (Inherited from DynamicValue.)

Reference

TwinCAT.TypeSystem Namespace

TwinCAT.TypeSystem.DynamicValue