IAdsAnyAccess.ReadAny Method (UInt32, UInt32, Type)

Reads data synchronously from an ADS device and writes it to an object.

Namespace:  TwinCAT.Ads
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

Object ReadAny(
    uint indexGroup,
    uint indexOffset,
    Type type
)

VB

Function ReadAny ( 
    indexGroup As UInteger,
    indexOffset As UInteger,
    type As Type
) As Object

Parameters

indexGroup

Type: System.UInt32
Index group of the ADS variable.

indexOffset

Type: System.UInt32
Index offset of the ADS variable.

type

Type: System.Type
Type of the object to be read.

Return Value

Type: Object
The object the read data is written to.

Reference

IAdsAnyAccess Interface

ReadAny Overload

TwinCAT.Ads Namespace