AdsSumCommandException Class

The exception that is thrown when an ADS SumCommand error occurs.

Inheritance Hierarchy

System.Object
  System.Exception
    System.ApplicationException
      TwinCAT.Ads.AdsException
        TwinCAT.Ads.AdsErrorException
          TwinCAT.Ads.AdsSumCommandException
Namespace:  TwinCAT.Ads
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

[SerializableAttribute]
public class AdsSumCommandException : AdsErrorException

VB

<SerializableAttribute>
Public Class AdsSumCommandException
    Inherits AdsErrorException

The AdsSumCommandException type exposes the following members.

Constructors

 

Name

Description

AdsSumCommandException Class 1:

AdsSumCommandException

Initializes a new Instance of the AdsErrorException class.

Properties

 

Name

Description

AdsSumCommandException Class 2:

Data

Gets a collection of key/value pairs that provide additional user-defined information about the exception. (Inherited from Exception.)

AdsSumCommandException Class 3:

ErrorCode

Gets the error code of the Exception. (Inherited from AdsErrorException.)

AdsSumCommandException Class 4:

HelpLink

Gets or sets a link to the help file associated with this exception. (Inherited from Exception.)

AdsSumCommandException Class 5:

HResult

Gets or sets HRESULT, a coded numerical value that is assigned to a specific exception. (Inherited from Exception.)

AdsSumCommandException Class 6:

InnerException

Gets the Exception instance that caused the current exception. (Inherited from Exception.)

AdsSumCommandException Class 7:

Message

Gets a message that describes the current exception. (Inherited from Exception.)

AdsSumCommandException Class 8:

Source

Gets or sets the name of the application or the object that causes the error. (Inherited from Exception.)

AdsSumCommandException Class 9:

StackTrace

Gets a string representation of the immediate frames on the call stack. (Inherited from Exception.)

AdsSumCommandException Class 10:

SumCommand

Gets the sum command.

AdsSumCommandException Class 11:

TargetSite

Gets the method that throws the current exception. (Inherited from Exception.)

Methods

 

Name

Description

AdsSumCommandException Class 12:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

AdsSumCommandException Class 13:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

AdsSumCommandException Class 14:

GetBaseException

When overridden in a derived class, returns the Exception that is the root cause of one or more subsequent exceptions. (Inherited from Exception.)

AdsSumCommandException Class 15:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

AdsSumCommandException Class 16:

GetObjectData

When overridden in a derived class, sets the SerializationInfo with information about the exception. (Overrides AdsErrorException.GetObjectData(SerializationInfo, StreamingContext).)

AdsSumCommandException Class 17:

GetType

Gets the runtime type of the current instance. (Inherited from Exception.)

AdsSumCommandException Class 18:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

AdsSumCommandException Class 19:

ToString

Creates and returns a string representation of the current exception. (Inherited from Exception.)

Events

 

Name

Description

AdsSumCommandException Class 20:

SerializeObjectState

Occurs when an exception is serialized to create an exception state object that contains serialized data about the exception. (Inherited from Exception.)

Reference

TwinCAT.Ads Namespace