Get-TcTargetInfo

SYNOPSIS

Get TwinCAT Device Target information.

SYNTAX

NetIdPort (Default)

Get-TcTargetInfo [[-NetId] <AmsNetId[]>] [-Timeout <Int32>] [-Force]
 [<CommonParameters>]

Route

Get-TcTargetInfo [-InputObject] <IRoute[]> [-Timeout <Int32>] [-Force]
 [<CommonParameters>]

AddressStr

Get-TcTargetInfo [-Address] <String[]> [-Timeout <Int32>] [-Force]
 [<CommonParameters>]

Session

Get-TcTargetInfo -Session <ISession[]> [-Timeout <Int32>] [-Force]
 [<CommonParameters>]

SessionId

Get-TcTargetInfo -SessionId <Int32[]> [-Timeout <Int32>] [-Force]
 [<CommonParameters>]

DESCRIPTION

This Cmdlet gets information from the specified target system. To contact the target system, it must be available as actual route. The information contains the TargetName, TwinCAT Version, Running Operating system, CPU Architecture and Image Information.

EXAMPLES

Example 1

PS> Get-TcTargetInfo

Target   NetId            Version    OS    Image Device CPUArch SystemId                             Fingerprint
------   -----            -------    --    ----- ------ ------- --------                             -----------
CX_11111 192.168.0.1.1.1  3.1.4026.2 Win10              AMD64   5b42297a-a9dd-6623-1780-e52074e54f71 2f72d63cba3069b5e1…

Get the target information of the local system.

Example 2

PS> Get-AdsRoute | Get-TcTargetInfo

Target          Version     Level OS     Image Device CPUArch
------          -------     ----- --     ----- ------ -------
CP-15ECA0       3.1.4021.50 CP    Win7                IntelX86
TC3TESTA1-CP67X 3.1.4021.54 CP    Win7                IntelX86

Get the target information of the actual connected routes.

PARAMETERS

-NetId

NetId(s) of the target system. Tab completion: Completes AmsNetId values from currently reachable routes on the local TwinCAT system. The net id.

Type: AmsNetId[]
Parameter Sets: NetIdPort
Aliases:

Required: False
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-InputObject

The route object where to get the Target information from.. Tab completion: Completes route names from currently reachable ADS systems on the local TwinCAT system. The input object.

Type: IRoute[]
Parameter Sets: Route
Aliases: Destination, Route

Required: True
Position: 1
Default value: None
Accept pipeline input: True (ByValue)
Accept wildcard characters: False

-Address

Target names/addresses. These can consist of RouteName, NetID, HostName or IPAddress. Wildcards are permitted. Tab completion: Completes route names from currently reachable ADS systems on the local TwinCAT system. The address.

Type: String[]
Parameter Sets: AddressStr
Aliases: Name

Required: True
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: True

-Session

The Session to use for the value read. The address.

Type: ISession[]
Parameter Sets: Session
Aliases:

Required: True
Position: Named
Default value: None
Accept pipeline input: True (ByValue)
Accept wildcard characters: False

-SessionId

Specifies the Session (with unique ID) to use for the value read. Tab completion: Completes IDs of active TwinCAT sessions (created with New-TcSession). The Session ID.

Type: Int32[]
Parameter Sets: SessionId
Aliases:

Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Timeout

The communication ADS timeout in milliseconds. A value of 0 disables the timeout. A value &lt;= 0 sets the Default (5000 ms). The ADS communication timeout in milliseconds.

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: -1
Accept pipeline input: False
Accept wildcard characters: False

-Force

Force reading value. This flag bypasses the FailFastInterceptor to retry communication in every case. Force flag.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

TwinCAT.IRoute[]

TwinCAT.ISession[]

OUTPUTS

NOTES