SymbolCollection Class
Interface represents a collection of ISymbol objects.
Inheritance Hierarchy
System.Object
TwinCAT.TypeSystem.Generic.InstanceCollection<ISymbol>
TwinCAT.TypeSystem.Generic.SymbolCollection<ISymbol>
TwinCAT.TypeSystem.SymbolCollection
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470
Syntax
C#
public class SymbolCollection : SymbolCollection<ISymbol>,
ISymbolCollection, ISymbolCollection<ISymbol>, IInstanceCollection<ISymbol>,
IList<ISymbol>, ICollection<ISymbol>, IEnumerable<ISymbol>,
IEnumerableThe SymbolCollection type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets the collection count.
| |
|
|
Returns an Empty Collection. | |
|
|
Gets the LIst of instances.
| |
|
|
The Path dictionary
| |
|
|
Gets a value indicating whether this instance is read only.
| |
|
|
Gets or sets the IInstance at the specified index.
| |
|
|
Gets the IInstance with the specified instance path.
| |
|
|
The mode this InstanceCollection<T> is working in.
|
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Adds the specified item.
| |
|
|
Adds the specified items to this collection.
| |
|
|
Returns a Read only version of this collection (shallow copy). | |
|
|
Clears this instance.
| |
|
|
Clones this instance. | |
|
|
Determines whether this collection contains the specified IInstance | |
|
|
Determines whether this collection contains an IInstance with the specified InstanceName / InstancePath
| |
|
|
Determines whether the specified instance name contains name.
| |
|
|
Copies this InstanceCollection<T> to the specified array.
| |
|
|
Determines whether the specified object is equal to the current object. | |
|
|
Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. | |
|
|
Gets the enumerator.
| |
|
|
Serves as the default hash function. | |
|
|
Gets the IInstanceby instance path.
| |
|
|
Gets the name of the instance by.
| |
|
|
Gets the Type of the current instance. | |
|
|
Determines the index of the specified IInstance.
| |
|
|
Inserts the specified IInstance at the specified index.
| |
|
|
Creates a shallow copy of the current Object. | |
|
|
Removes the specified item.
| |
|
|
Removes the IInstance at the specified index.
| |
|
|
Returns a string that represents the current object. | |
|
|
Tries to get the IInstance. of the specified path.
| |
|
|
Tries to get Instances by name.
| |
|
|
Try to get instances with predicate function
|
Extension Methods
|
|
Name |
Description |
|---|---|---|
|
|
Filters the symbols collection for symbols with a specific Attribute value.
|