RpcMethodParameterCollection Class
Collection of RPC method parameters
Inheritance Hierarchy
SystemObject
TwinCAT.TypeSystemRpcMethodParameterCollection
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470
Syntax
C#
public class RpcMethodParameterCollection : IRpcMethodParameterCollection,
IList<IRpcMethodParameter>, ICollection<IRpcMethodParameter>, IEnumerable<IRpcMethodParameter>,
IEnumerableThe RpcMethodParameterCollection type exposes the following members.
Constructors
|
|
Name |
Description |
|---|---|---|
|
|
Initializes a new instance of the RpcMethodParameterCollection class. | |
|
|
RpcMethodParameterCollection(IEnumerableIRpcMethodParameter) |
Initializes a new instance of the RpcMethodParameterCollection class. |
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets the number of elements contained in the ICollectionT. | |
|
|
Gets an Empty RpcMethodParameterCollection | |
|
|
Gets a value indicating whether the ICollectionT is read-only. | |
|
|
Gets or sets the element at the specified index. |
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Adds an item to the ICollectionT. | |
|
|
Returns a read only version of this RpcMethodParameterCollection | |
|
|
Removes all items from the ICollectionT. | |
|
|
Determines whether the ICollectionT contains a specific value. | |
|
|
Copies to. | |
|
|
Determines whether the specified object is equal to the current
object. | |
|
|
Allows an object to try to free resources and perform other
cleanup operations before it is reclaimed by garbage
collection. | |
|
|
Returns an enumerator that iterates through the collection. | |
|
|
Serves as the default hash function. | |
|
|
Gets the length is parameter. | |
|
|
Gets the Type of the current
instance. | |
|
|
Determines the index of a specific item in the IListT. | |
|
|
Inserts an item to the IListT at the specified index. | |
|
|
Creates a shallow copy of the current Object. | |
|
|
Removes the first occurrence of a specific object from the ICollectionT. | |
|
|
Removes the IListT item at the specified index. | |
|
|
Returns a string that represents the current object. |
- RpcMethodParameterCollection.Count Property
- RpcMethodParameterCollection.IsReadOnly Property
- RpcMethodParameterCollection.Item Property
- RpcMethodParameterCollection.Empty Property
- RpcMethodParameterCollection.Add Method
- RpcMethodParameterCollection.AsReadOnly Method
- RpcMethodParameterCollection.Clear Method
- RpcMethodParameterCollection.Contains Method
- RpcMethodParameterCollection.CopyTo Method
- RpcMethodParameterCollection.GetEnumerator Method
- RpcMethodParameterCollection.GetLengthIsParameter Method
- RpcMethodParameterCollection.IndexOf Method
- RpcMethodParameterCollection.Insert Method
- RpcMethodParameterCollection.Remove Method
- RpcMethodParameterCollection.RemoveAt Method
- RpcMethodParameterCollection Constructor (IEnumerable.IRpcMethodParameter.)