IValueSymbol Properties

The IValueSymbol type exposes the following members.

Properties

 

Name

Description

IValueSymbol Properties 1:

AccessRights

Gets the access rights.

IValueSymbol Properties 2:

Attributes

Gets the Type Attributes.
(Inherited from IAttributedInstance)

IValueSymbol Properties 3:

BitSize

Gets the size of the IDataType in bits.
(Inherited from IBitSize)

IValueSymbol Properties 4:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from IBitSize)

IValueSymbol Properties 5:

Category

Gets the Symbol/Datatype Category
(Inherited from ISymbol)

IValueSymbol Properties 6:

Comment

Gets the comment of the IInstance
(Inherited from IInstance)

IValueSymbol Properties 7:

Connection

Gets the connection that produces values for this IValueSymbol

IValueSymbol Properties 8:

DataType

Gets the IDataType of the IInstance.
(Inherited from IInstance)

IValueSymbol Properties 9:

HasValue

Gets a value indicating whether this IValueSymbol has a value.
(Inherited from IValueRawSymbol)

IValueSymbol Properties 10:

InstanceName

Gets the name of the instance (without periods (.)
(Inherited from IInstance)

IValueSymbol Properties 11:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.))
(Inherited from IInstance)

IValueSymbol Properties 12:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping
(Inherited from IBitSize)

IValueSymbol Properties 13:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from IBitSize)

IValueSymbol Properties 14:

IsContainerType

Gets a value indicating whether this Symbol is acontainer type.
(Inherited from ISymbol)

IValueSymbol Properties 15:

IsPersistent

Gets a value indicating whether this ISymbol is persistent.
(Inherited from ISymbol)

IValueSymbol Properties 16:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO)
(Inherited from IInstance)

IValueSymbol Properties 17:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type.
(Inherited from ISymbol)

IValueSymbol Properties 18:

IsProperty

Gets a value indicating whether IInstance is a property.
(Inherited from IInstance)

IValueSymbol Properties 19:

IsReadOnly

Indicates that this instance is read only.
(Inherited from ISymbol)

IValueSymbol Properties 20:

IsRecursive

Gets a value indicating whether this instance is recursive.
(Inherited from ISymbol)

IValueSymbol Properties 21:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO)
(Inherited from IInstance)

IValueSymbol Properties 22:

IsStatic

Gets a value indicating whether this IInstance is static.
(Inherited from IInstance)

IValueSymbol Properties 23:

NotificationSettings

Gets or sets the notification settings.

IValueSymbol Properties 24:

Parent

Gets the parent Symbol
(Inherited from ISymbol)

IValueSymbol Properties 25:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType
(Inherited from IBitSize)

IValueSymbol Properties 26:

SubSymbols

Gets the SubSymbols of the ISymbol
(Inherited from ISymbol)

IValueSymbol Properties 27:

TypeName

Gets the name of the DataType that is used for this IInstance.
(Inherited from IInstance)

IValueSymbol Properties 28:

ValueAccessor

Gets the value accessor.
(Inherited from IValueRawSymbol)

IValueSymbol Properties 29:

ValueEncoding

Gets the value encoding.
(Inherited from IAttributedInstance)

See Also

Reference

IValueSymbol Interface TwinCAT.TypeSystem Namespace