IValueAnySymbol Interface

Interface IValueAnySymbol


Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public interface IValueAnySymbol : ISymbol, 
IAttributedInstance, IInstance, IBitSize

The IValueAnySymbol type exposes the following members.

Properties

 

Name

Description

IValueAnySymbol Interface 1:

Attributes

Gets the Type Attributes.
(Inherited from IAttributedInstance)

IValueAnySymbol Interface 2:

BitSize

Gets the size of the IDataType in bits.
(Inherited from IBitSize)

IValueAnySymbol Interface 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from IBitSize)

IValueAnySymbol Interface 4:

Category

Gets the Symbol/Datatype Category
(Inherited from ISymbol)

IValueAnySymbol Interface 5:

Comment

Gets the comment of the IInstance
(Inherited from IInstance)

IValueAnySymbol Interface 6:

DataType

Gets the IDataType of the IInstance.
(Inherited from IInstance)

IValueAnySymbol Interface 7:

InstanceName

Gets the name of the instance (without periods (.)
(Inherited from IInstance)

IValueAnySymbol Interface 8:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.))
(Inherited from IInstance)

IValueAnySymbol Interface 9:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping
(Inherited from IBitSize)

IValueAnySymbol Interface 10:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from IBitSize)

IValueAnySymbol Interface 11:

IsContainerType

Gets a value indicating whether this Symbol is acontainer type.
(Inherited from ISymbol)

IValueAnySymbol Interface 12:

IsPersistent

Gets a value indicating whether this ISymbol is persistent.
(Inherited from ISymbol)

IValueAnySymbol Interface 13:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO)
(Inherited from IInstance)

IValueAnySymbol Interface 14:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type.
(Inherited from ISymbol)

IValueAnySymbol Interface 15:

IsProperty

Gets a value indicating whether IInstance is a property.
(Inherited from IInstance)

IValueAnySymbol Interface 16:

IsReadOnly

Indicates that this instance is read only.
(Inherited from ISymbol)

IValueAnySymbol Interface 17:

IsRecursive

Gets a value indicating whether this instance is recursive.
(Inherited from ISymbol)

IValueAnySymbol Interface 18:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO)
(Inherited from IInstance)

IValueAnySymbol Interface 19:

IsStatic

Gets a value indicating whether this IInstance is static.
(Inherited from IInstance)

IValueAnySymbol Interface 20:

Parent

Gets the parent Symbol
(Inherited from ISymbol)

IValueAnySymbol Interface 21:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType
(Inherited from IBitSize)

IValueAnySymbol Interface 22:

SubSymbols

Gets the SubSymbols of the ISymbol
(Inherited from ISymbol)

IValueAnySymbol Interface 23:

TypeName

Gets the name of the DataType that is used for this IInstance.
(Inherited from IInstance)

IValueAnySymbol Interface 24:

ValueEncoding

Gets the value encoding.
(Inherited from IAttributedInstance)

Methods

 

Name

Description

IValueAnySymbol Interface 25:

ReadAnyValue(Type)

Reads the value of this Value into a new created instance of the managed type

IValueAnySymbol Interface 26:

ReadAnyValue(Type, Int32)

Reads the value of this Value into a new created instance of the managed type

IValueAnySymbol Interface 27:

ReadAnyValue<T>()

Reads the value of this Value into a new created instance of the managed type

IValueAnySymbol Interface 28:

ReadAnyValue<T>(Int32)

Reads the value of this Value into a new created instance of the managed type

IValueAnySymbol Interface 29:

ReadAnyValueAsync(Type, CancellationToken)

Reads the (AnyType) value asynchronously.

IValueAnySymbol Interface 30:

ReadAnyValueAsync<T>(CancellationToken)

Reads the (AnyType) value asynchronously.

IValueAnySymbol Interface 31:

UpdateAnyValue(Object)

Reads the value of this Value into the specified managed value.

IValueAnySymbol Interface 32:

UpdateAnyValue(Object, Int32)

Reads the value of this Value into the specified managed value.

IValueAnySymbol Interface 33:

WriteAnyValue(Object)

Writes the value represented by the managed value to this Value

IValueAnySymbol Interface 34:

WriteAnyValue(Object, Int32)

Writes the value represented by the managed value to this Value

Extension Methods

 

Name

Description

HasExternalDataReferences

Indicates, that the Instance value includes process memory data, that cannot be read in one memory block.
(Defined by DataTypeExtension)

IsExternalDataReference

Indicates, that the field is static or is not part of the parents processimage memory location
(Defined by DataTypeExtension)

Unwrap

Gets the Unwrapped Symbol
(Defined by SymbolExtensions)

See Also

Reference

TwinCAT.TypeSystem Namespace ISymbol

Beckhoff Automation GmbH & Co. KG 2001-2026