IStringType Interface
Interface representing a string IDataType
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads.Abstractions (in
TwinCAT.Ads.Abstractions.dll) Version: 6.0.328+39e3229
Syntax
C#
public interface IStringType : IDataType,
IBitSize
The IStringType type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets the attributes of the IDataType (Inherited from IDataType.) | |
|
|
Gets the size of the IDataType in bits. (Inherited from IBitSize.) | |
|
|
Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.) | |
|
|
Gets the Data Type category (Inherited from IDataType.) | |
|
|
Gets the comment behind the variable declaration. (Inherited from IDataType.) | |
|
|
Gets the encoding of the String (Encoding.Default (STRING) or Encoding.UNICODE (WSTRING)) | |
|
|
Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.) | |
|
|
Gets the ID of the DataType (Inherited from IDataType.) | |
|
|
Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.) | |
|
|
Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.) | |
|
|
Gets a value indicating whether the string is of fixed length. | |
|
|
Gets the number of characters within the string (when fixed length). | |
|
|
Gets the name of the Data Type (without namespace) (Inherited from IDataType.) | |
|
|
Gets the namespace string within the IDataType exists. (Inherited from IDataType.) | |
|
|
Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.) |
Extension Methods
|
|
Name |
Description |
|---|---|---|
|
|
Overloaded. Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.) | |
|
|
Overloaded. Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.) | |
|
|
Overloaded. Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.) | |
|
|
Overloaded. Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.) | |
|
|
Gets a value indicating whether this IDataType is a pointer type (Defined by DataTypeExtension.) | |
|
|
Overloaded. Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.) | |
|
|
Overloaded. Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.) | |
|
|
Gets a value indicating whether this IDataType is a reference type (Defined by DataTypeExtension.) | |
|
|
Indicates, that the Instance value includes process memory data, that cannot be read in one memory block. (Defined by DataTypeExtension.) | |
|
|
Overloaded. Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.) | |
|
|
Overloaded. Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.) | |
|
|
Overloaded. Resolves the specified data type for AliasReference (Defined by DataTypeExtension.) | |
|
|
Overloaded. Resolves the specified strategy. (Defined by DataTypeExtension.) |