IRpcMethodParameterCollection Interface

Interface IRpcMethodParameterCollection

Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 6.0.328+39e3229

Syntax

C#

public interface IRpcMethodParameterCollection : IList<IRpcMethodParameter>, 
    ICollection<IRpcMethodParameter>, IEnumerable<IRpcMethodParameter>, IEnumerable

The IRpcMethodParameterCollection type exposes the following members.

Properties

 

Name

Description

IRpcMethodParameterCollection Interface 1:

Count

Gets the number of elements contained in the ICollection.T.. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 2:

IsReadOnly

Gets a value indicating whether the ICollection.T. is read-only. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 3:

Item

Gets or sets the element at the specified index. (Inherited from IList.IRpcMethodParameter..)

Methods

 

Name

Description

IRpcMethodParameterCollection Interface 4:

Add

Adds an item to the ICollection.T.. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 5:

Clear

Removes all items from the ICollection.T.. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 6:

Contains

Determines whether the ICollection.T. contains a specific value. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 7:

CopyTo

Copies the elements of the ICollection.T. to an Array, starting at a particular Array index. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 8:

GetEnumerator

Returns an enumerator that iterates through the collection. (Inherited from IEnumerable.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 9:

GetLengthIsParameter

Gets the corresponding LengthIs parameter.

IRpcMethodParameterCollection Interface 10:

IndexOf

Determines the index of a specific item in the IList.T.. (Inherited from IList.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 11:

Insert

Inserts an item to the IList.T. at the specified index. (Inherited from IList.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 12:

Remove

Removes the first occurrence of a specific object from the ICollection.T.. (Inherited from ICollection.IRpcMethodParameter..)

IRpcMethodParameterCollection Interface 13:

RemoveAt

Removes the IList.T. item at the specified index. (Inherited from IList.IRpcMethodParameter..)

Reference

TwinCAT.TypeSystem Namespace