IEnumType Methods

The IEnumType type exposes the following members.

Methods

 

Name

Description

IEnumType Methods 1:

Contains

Determines whether the enum values contains the specified name

IEnumType Methods 2:

GetNames

Gets the filed names of the IEnumType.T.

IEnumType Methods 3:

GetValues

Gets the values of the IEnumType.T.

IEnumType Methods 4:

Parse

Parses a value name of the IEnumType.T. and returns the value (as base type)

IEnumType Methods 5:

ToString

Returns a String that represents the specified value.

IEnumType Methods 6:

TryParse(String, IConvertible.)

Parses the value from value name.

IEnumType Methods 7:

TryParse(String, IEnumValue.)

Parses the value from value name.

Extension Methods

 

Name

Description

IsArrayOfPrimitives.

Overloaded.

Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.)

IsArrayOfPrimitives(Boolean)

Overloaded.

Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.)

IsContainer.

Overloaded.

Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.)

IsContainer(Boolean)

Overloaded.

Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.)

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Defined by DataTypeExtension.)

IsPrimitive.

Overloaded.

Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.)

IsPrimitive(Boolean)

Overloaded.

Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.)

IsReference

Gets a value indicating whether this IDataType is a reference type (Defined by DataTypeExtension.)

ReferencesExternalData

Indicates, that the Instance value includes process memory data, that cannot be read in one memory block. (Defined by DataTypeExtension.)

ResolvableAsPrimitive.

Overloaded.

Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.)

ResolvableAsPrimitive(Boolean)

Overloaded.

Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.)

Resolve.

Overloaded.

Resolves the specified data type for AliasReference (Defined by DataTypeExtension.)

Resolve(DataTypeResolveStrategy)

Overloaded.

Resolves the specified strategy. (Defined by DataTypeExtension.)

Reference

IEnumType Interface

TwinCAT.TypeSystem Namespace