IDynamicSymbol Interface
Interface IDynamicSymbol
          Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads.Abstractions (in
TwinCAT.Ads.Abstractions.dll) Version: 6.0.328+39e3229
Syntax
C#
public interface IDynamicSymbol : ISymbol,
IAttributedInstance, IInstance, IBitSize
The IDynamicSymbol type exposes the following members.
Properties
| 
 | Name | Description | 
|---|---|---|
| 
                     | Gets the Type Attributes. (Inherited from IAttributedInstance.) | |
| 
                     | Gets the size of the IDataType in bits. (Inherited from IBitSize.) | |
| 
                     | Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.) | |
| 
                     | Gets the Symbol/Datatype Category (Inherited from ISymbol.) | |
| 
                     | Gets the comment of the IInstance (Inherited from IInstance.) | |
| 
                     | Gets the IDataType of the IInstance. (Inherited from IInstance.) | |
| 
                     | Gets the name of the instance (without periods (.) (Inherited from IInstance.) | |
| 
                     | Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from IInstance.) | |
| 
                     | Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.) | |
| 
                     | Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.) | |
| 
                     | Gets a value indicating whether this Symbol is acontainer type. (Inherited from ISymbol.) | |
| 
                     | Gets a value indicating whether this ISymbol is persistent. (Inherited from ISymbol.) | |
| 
                     | Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from IInstance.) | |
| 
                     | Gets a value indicating whether this instance is a primitive type. (Inherited from ISymbol.) | |
| 
                     | Indicates that this instance is read only. (Inherited from ISymbol.) | |
| 
                     | Gets a value indicating whether this instance is recursive. (Inherited from ISymbol.) | |
| 
                     | Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from IInstance.) | |
| 
                     | Gets a value indicating whether this IInstance is static. (Inherited from IInstance.) | |
| 
                     | Gets the normalized instance name (fixed name for dynamic property access) | |
| 
                     | Gets the parent Symbol (Inherited from ISymbol.) | |
| 
                     | Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.) | |
| 
                     | Gets the SubSymbols of the ISymbol (Inherited from ISymbol.) | |
| 
                     | Gets the name of the DataType that is used for this IInstance. (Inherited from IInstance.) | |
| 
                     | Gets the value encoding. (Inherited from IAttributedInstance.) | 
Extension Methods
| 
 | Name | Description | 
|---|---|---|
| 
 | Indicates, that the Instance value includes process memory data, that cannot be read in one memory block. (Defined by DataTypeExtension.) | 