SymbolIterator Class
Iterator class for enumerations of Symbols.
Inheritance Hierarchy
System.Object
  TwinCAT.TypeSystem.Generic.SymbolIterator.ISymbol.
    TwinCAT.Ads.TypeSystem.SymbolIterator
Namespace:  TwinCAT.Ads.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 6.0.328+39e3229
Syntax
C#
public class SymbolIterator : SymbolIterator<ISymbol>
The SymbolIterator type exposes the following members.
Constructors
| 
                   
  | 
                   Name  | 
                   Description  | 
|---|---|---|
| 
                   
                      | 
                   Initializes a new instance of the SymbolIterator class.  | |
| 
                   
                      | 
                   Initializes a new instance of the SymbolIterator class.  | |
| 
                   
                      | 
                   SymbolIterator(IInstanceCollection.ISymbol., Func.ISymbol, Boolean.)  | 
                   Initializes a new instance of the SymbolIterator class.  | 
| 
                   
                      | 
                   SymbolIterator(IEnumerable.ISymbol., Boolean, Func.ISymbol, Boolean.)  | 
                   Initializes a new instance of the SymbolIterator class.  | 
| 
                   
                      | 
                   Initializes a new instance of the SymbolIterator class.  | 
Properties
| 
                   
  | 
                   Name  | 
                   Description  | 
|---|---|---|
| 
                   
                      | 
                   Gets or sets the SymbolIterationMask (Inherited from SymbolIterator.T..)  | |
| 
                   
                      | 
                   Gets or sets a value indicating whether the iterator checks for Symbol recursions (true by default). (Inherited from SymbolIterator.T..)  | 
Methods
| 
                   
  | 
                   Name  | 
                   Description  | 
|---|---|---|
| 
                   
                      | 
                   Equals  | 
                   Determines whether the specified object is equal to the current object. (Inherited from Object.)  | 
| 
                   
                      | 
                   Finalize  | 
                   Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)  | 
| 
                   
                      | 
                   Gets the enumerator that enumerates through a collection (Inherited from SymbolIterator.T..)  | |
| 
                   
                      | 
                   GetHashCode  | 
                   Serves as the default hash function. (Inherited from Object.)  | 
| 
                   
                      | 
                   GetType  | 
                   Gets the Type of the current instance. (Inherited from Object.)  | 
| 
                   
                      | 
                   MemberwiseClone  | 
                   Creates a shallow copy of the current Object. (Inherited from Object.)  | 
| 
                   
                      | 
                   ToString  | 
                   Returns a string that represents the current object. (Inherited from Object.)  | 
Remarks
This iterator class can be used to iterate over collections of symbol trees (root symbols + sub symbols). By constructor the user can choose if the iterator works recursively within the symbol tree and optionally a filter function to select only specific symbols (predicate).
Examples
The following example shows how to determine, browse and filter symbols.
Browsing and filtering Symbols
using (AdsClient client = new AdsClient())
{
CancellationToken cancel = CancellationToken.None;
uint valueToRead = 0;
uint valueToWrite = 42;
client.Connect(AmsNetId.Local, 851);
// Load all Symbols + DataTypes
ISymbolLoader loader = SymbolLoaderFactory.Create(client, SymbolLoaderSettings.Default);
ResultSymbols resultSymbols = await loader.GetSymbolsAsync(cancel);
if (resultSymbols.Succeeded)
{
Symbol symbol = (Symbol)resultSymbols.Symbols["MAIN.nCounter"];
// Works for ALL Primitive 'ANY TYPES' Symbols
ResultWriteAccess resultWrite = await symbol.WriteValueAsync(valueToWrite, cancel);
ResultReadValueAccess resultRead = await symbol.ReadValueAsync(cancel);
if (resultRead.Succeeded)
valueToRead = (uint)resultRead.Value;
// Simple filtering of Symbols
Regex filterExpression = new Regex(pattern: @"^MAIN.*"); // Everything that starts with "MAIN"
// FilterFunction that filters for the InstancePath
Func<ISymbol, bool> filter = s => filterExpression.IsMatch(s.InstancePath);
SymbolIterator iterator = new SymbolIterator(symbols: resultSymbols.Symbols, recurse: true, selector: filter);
foreach (ISymbol filteredSymbol in iterator)
{
Console.WriteLine(filteredSymbol.InstancePath);
}
}
}