PointerType Class

Represents a pointer type.

Inheritance Hierarchy

System.Object
  TwinCAT.Ads.TypeSystem.DataType
    TwinCAT.Ads.TypeSystem.PointerType
      TwinCAT.Ads.TypeSystem.PCCHType
      TwinCAT.Ads.TypeSystem.PVoidType

Namespace: TwinCAT.Ads.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public class PointerType : DataType, 
IPointerType, IDataType, IBitSize

The PointerType type exposes the following members.

Properties

 

Name

Description

PointerType Class 1:

Attributes

Gets the attributes of the IDataType
(Inherited from DataType)

PointerType Class 2:

BitSize

Gets the size of the DataType in bits.
(Inherited from DataType)

PointerType Class 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from DataType)

PointerType Class 4:

Category

Gets the Data Type category
(Inherited from DataType)

PointerType Class 5:

Comment

Gets the comment.
(Inherited from DataType)

PointerType Class 6:

FullName

Gets the full name of the IDataType (Namespace + Name)
(Inherited from DataType)

PointerType Class 7:

Id

Gets the ID of the DataType
(Inherited from DataType)

PointerType Class 8:

IsBitType

Gets a value indicating whether this IDataType is a bit mapping Type
(Inherited from DataType)

PointerType Class 9:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from DataType)

PointerType Class 10:

ManagedType

Gets the corresponding .NET Type if attached.
(Overrides DataType.ManagedType)

PointerType Class 11:

Name

Gets the name of the Data Type (without namespace)
(Inherited from DataType)

PointerType Class 12:

Namespace

Gets the namespace string within the IDataType exists.
(Inherited from DataType)

PointerType Class 13:

ReferencedType

Gets the the referenced type.

PointerType Class 14:

ReferenceTypeName

Gets the name of the referenced datatype

PointerType Class 15:

Size

Gets the Size of the DataType in Bytes or bits.
(Inherited from DataType)

PointerType Class 16:

TypeGuid

Gets the Guid of the DataType (optional)
(Inherited from DataType)

Methods

 

Name

Description

PointerType Class 17:

Equals

Determines whether the specified object is equal to the current object.
(Inherited from Object)

PointerType Class 18:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)

PointerType Class 19:

GetHashCode

Serves as the default hash function.
(Inherited from Object)

PointerType Class 20:

GetType

Gets the Type of the current instance.
(Inherited from Object)

PointerType Class 21:

MemberwiseClone

Creates a shallow copy of the current Object.
(Inherited from Object)

PointerType Class 22:

ToString

Returns a String that represents this instance.
(Inherited from DataType)

Extension Methods

 

Name

Description

HasExternalDataReferences

Indicates, that the Instance value includes process memory data, that cannot be read in one memory block.
(Defined by DataTypeExtension)

IsArrayOfPrimitives

Determines whether the dataType is an array of Primitives.
(Defined by DataTypeExtension)

IsArrayOfPrimitives

Determines whether the dataType is an array of Primitives.
(Defined by DataTypeExtension)

IsContainer

Gets a value indicating whether this IDataType is a container type
(Defined by DataTypeExtension)

IsContainer

Gets a value indicating whether this IDataType is a container type
(Defined by DataTypeExtension)

IsPointer

Gets a value indicating whether this IDataType is a pointer type
(Defined by DataTypeExtension)

IsPrimitive

Gets a value indicating whether this IDataType is primitive
(Defined by DataTypeExtension)

IsPrimitive

Gets a value indicating whether this IDataType is primitive
(Defined by DataTypeExtension)

IsReference

Gets a value indicating whether this IDataType is a reference type
(Defined by DataTypeExtension)

ResolvableAsPrimitive

Indicates, that this data type can be resolved as primitive or primmitive Array.
(Defined by DataTypeExtension)

ResolvableAsPrimitive

Indicates, that this data type can be resolved as primitive or primmitive Array.
(Defined by DataTypeExtension)

Resolve

Resolves the specified data type for AliasReference (Resolving the IAliasType/IReferenceType)
(Defined by DataTypeExtension)

Resolve

Resolves the specified strategy.
(Defined by DataTypeExtension)

See Also

Reference

TwinCAT.Ads.TypeSystem Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026